Pengukuran Karakteristik Dielektrik Minyak Goreng Berdasarkan Lama Pemanasan Menggunakan Rangkaian Sederhana Multivibrator IC 555

Misto Misto, Muhtarom Y.A, Supriyadi Supriyadi
{"title":"Pengukuran Karakteristik Dielektrik Minyak Goreng Berdasarkan Lama Pemanasan Menggunakan Rangkaian Sederhana Multivibrator IC 555","authors":"Misto Misto, Muhtarom Y.A, Supriyadi Supriyadi","doi":"10.32528/ELKOM.V1I1.2177","DOIUrl":null,"url":null,"abstract":"An electronic system for cooking oil dielectric  constant measurement have been done. The system was employed an capacitive sensor, IC Timer 555, oscilloscope, and power supply. The cooking oil is placed in a capacitive sensor as part of unstable multivibrator IC 555 circuit. The samples(labeled and non labeled) temperature was condisioned on room temperature and at 100 ⁰C with the heated time duration of 1 hours, 2 hours, and 3 hours treatment.   The result of  the measurement shows that all sample with time duration 1 hours and 2 hours increases but with time duration 3 hours turn down.","PeriodicalId":288340,"journal":{"name":"Jurnal Teknik Elektro dan Komputasi (ELKOM)","volume":"31 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-08-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Teknik Elektro dan Komputasi (ELKOM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.32528/ELKOM.V1I1.2177","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

An electronic system for cooking oil dielectric  constant measurement have been done. The system was employed an capacitive sensor, IC Timer 555, oscilloscope, and power supply. The cooking oil is placed in a capacitive sensor as part of unstable multivibrator IC 555 circuit. The samples(labeled and non labeled) temperature was condisioned on room temperature and at 100 ⁰C with the heated time duration of 1 hours, 2 hours, and 3 hours treatment.   The result of  the measurement shows that all sample with time duration 1 hours and 2 hours increases but with time duration 3 hours turn down.
研制了食用油介电常数电子测量系统。该系统采用电容式传感器、IC定时器555、示波器和电源。食用油被放置在电容式传感器中,作为不稳定多振器IC 555电路的一部分。样品(标记和未标记)温度条件为室温和100⁰C,加热时间持续时间为1小时、2小时和3小时。测量结果表明,时间持续1小时和2小时的样品均增加,而时间持续3小时的样品则下降。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信