{"title":"Power quality improvement using a shunt active power filter based on an cascaded H-bridge eleven level inverter with predictive current control","authors":"Yousfi Abdelkader, A. Chaker, Y. Bot","doi":"10.11591/IJAPE.V10.I3.PP%P","DOIUrl":null,"url":null,"abstract":"The active power filter has proven to be an effective method for attenuating harmonic currents generated by non-linear loads as well as for compensating reactive power. This paper presents a comparison study between two control methods associated with a shunt active power filter based on eleven-level type cascaded inverter. The first method is based on the conventional PI regulator and the second is based on the predictive current controller. The eleven-level type cascade inverter has more advantages relatively to the two-level inverter; among them: better total harmonic distortion, reduced semiconductor switches ratings and reduced switching losses. The performance of the APF is tested by simulation using Matlab/Simulink. The predictive controlled the APF associated with the multi-level inverter shows more performances and efficiency compared to the conventional control algorithms.","PeriodicalId":280098,"journal":{"name":"International Journal of Applied Power Engineering","volume":"473 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Applied Power Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11591/IJAPE.V10.I3.PP%P","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The active power filter has proven to be an effective method for attenuating harmonic currents generated by non-linear loads as well as for compensating reactive power. This paper presents a comparison study between two control methods associated with a shunt active power filter based on eleven-level type cascaded inverter. The first method is based on the conventional PI regulator and the second is based on the predictive current controller. The eleven-level type cascade inverter has more advantages relatively to the two-level inverter; among them: better total harmonic distortion, reduced semiconductor switches ratings and reduced switching losses. The performance of the APF is tested by simulation using Matlab/Simulink. The predictive controlled the APF associated with the multi-level inverter shows more performances and efficiency compared to the conventional control algorithms.