S. Carlier, T. Marwick, P. Segers, P. Verdonck, G. Camp, B. Cosyns, James D. Thomas
{"title":"Non-invasive evaluation of left ventricular power output by simultaneous recordings of applanation tonometry and echocardiographic Doppler signals","authors":"S. Carlier, T. Marwick, P. Segers, P. Verdonck, G. Camp, B. Cosyns, James D. Thomas","doi":"10.1109/CIC.1997.647871","DOIUrl":null,"url":null,"abstract":"Ventricular hydraulic power is defined as the instantaneous product of flow and pressure at the aortic root. This paper describes a system for non-invasive determination of LV power output based on simultaneous acquisition of applanation tonometry for aortic blood pressure (BP) evaluation and echo-Doppler signals for flow measurement. Acquisition is performed with a dedicated A/D system allowing on-line visualisation of Doppler power spectra and calibrated tonometric signals (using mean and diastolic cuff BP at the brachial level). Aortic BP is estimated either using an aorto-radial transfer function, either untransformed carotid BP. This method has been investigated in 10 normal volunteers. Visualisation of calibrated data during acquisition allowed recordings with a low variability (mean standard deviation of reconstructed systolic BP<5 mmHg). The expected increase in systolic BP was observed from carotid to radial sites. The mean peak power was 6/spl plusmn/2 W.","PeriodicalId":228649,"journal":{"name":"Computers in Cardiology 1997","volume":"45 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1997-09-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computers in Cardiology 1997","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CIC.1997.647871","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4
Abstract
Ventricular hydraulic power is defined as the instantaneous product of flow and pressure at the aortic root. This paper describes a system for non-invasive determination of LV power output based on simultaneous acquisition of applanation tonometry for aortic blood pressure (BP) evaluation and echo-Doppler signals for flow measurement. Acquisition is performed with a dedicated A/D system allowing on-line visualisation of Doppler power spectra and calibrated tonometric signals (using mean and diastolic cuff BP at the brachial level). Aortic BP is estimated either using an aorto-radial transfer function, either untransformed carotid BP. This method has been investigated in 10 normal volunteers. Visualisation of calibrated data during acquisition allowed recordings with a low variability (mean standard deviation of reconstructed systolic BP<5 mmHg). The expected increase in systolic BP was observed from carotid to radial sites. The mean peak power was 6/spl plusmn/2 W.