Non-invasive evaluation of left ventricular power output by simultaneous recordings of applanation tonometry and echocardiographic Doppler signals

S. Carlier, T. Marwick, P. Segers, P. Verdonck, G. Camp, B. Cosyns, James D. Thomas
{"title":"Non-invasive evaluation of left ventricular power output by simultaneous recordings of applanation tonometry and echocardiographic Doppler signals","authors":"S. Carlier, T. Marwick, P. Segers, P. Verdonck, G. Camp, B. Cosyns, James D. Thomas","doi":"10.1109/CIC.1997.647871","DOIUrl":null,"url":null,"abstract":"Ventricular hydraulic power is defined as the instantaneous product of flow and pressure at the aortic root. This paper describes a system for non-invasive determination of LV power output based on simultaneous acquisition of applanation tonometry for aortic blood pressure (BP) evaluation and echo-Doppler signals for flow measurement. Acquisition is performed with a dedicated A/D system allowing on-line visualisation of Doppler power spectra and calibrated tonometric signals (using mean and diastolic cuff BP at the brachial level). Aortic BP is estimated either using an aorto-radial transfer function, either untransformed carotid BP. This method has been investigated in 10 normal volunteers. Visualisation of calibrated data during acquisition allowed recordings with a low variability (mean standard deviation of reconstructed systolic BP<5 mmHg). The expected increase in systolic BP was observed from carotid to radial sites. The mean peak power was 6/spl plusmn/2 W.","PeriodicalId":228649,"journal":{"name":"Computers in Cardiology 1997","volume":"45 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1997-09-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computers in Cardiology 1997","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CIC.1997.647871","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

Ventricular hydraulic power is defined as the instantaneous product of flow and pressure at the aortic root. This paper describes a system for non-invasive determination of LV power output based on simultaneous acquisition of applanation tonometry for aortic blood pressure (BP) evaluation and echo-Doppler signals for flow measurement. Acquisition is performed with a dedicated A/D system allowing on-line visualisation of Doppler power spectra and calibrated tonometric signals (using mean and diastolic cuff BP at the brachial level). Aortic BP is estimated either using an aorto-radial transfer function, either untransformed carotid BP. This method has been investigated in 10 normal volunteers. Visualisation of calibrated data during acquisition allowed recordings with a low variability (mean standard deviation of reconstructed systolic BP<5 mmHg). The expected increase in systolic BP was observed from carotid to radial sites. The mean peak power was 6/spl plusmn/2 W.
通过同时记录压压血压计和超声心动图多普勒信号无创评估左心室功率输出
心室水力被定义为主动脉根部流量和压力的瞬时乘积。本文介绍了一种基于同时采集主动脉压压测量和血流测量回波多普勒信号的无创低压功率输出测定系统。采集是通过专用的a /D系统进行的,该系统允许在线可视化多普勒功率谱和校准的血压计信号(使用臂水平的平均和舒张袖带血压)。使用主动脉-桡动脉传递函数或未转化的颈动脉血压来估计主动脉血压。这种方法已在10名正常志愿者身上进行了试验。在采集过程中,校准数据的可视化允许记录低变异性(重建收缩压的平均标准偏差<5 mmHg)。从颈动脉到桡动脉部位的预期收缩压升高。平均峰值功率为6/spl + 2 W。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信