M. Hazumi, T. Kawasaki, K. Senyo, Y. Nagashima, K. Yamamoto, K. Yamamura, T. Tsuboyama, J. Haba, H. Ikeda, H. Iwasaki, T. Matsuda, H. Ozaki, M. Tanaka, Y. Yamada, S. Okuno, S. Avrillon, Y. Asano, S. Mori, C. Fukunaga, T. Hirose, H. Miyata, K. Miyano, E. Banas, A. Bozek, Z. Natkaniec, H. Palka, M. Różańska, K. Rybicki
{"title":"Evaluation of silicon micro strip detectors with large read-out pitch","authors":"M. Hazumi, T. Kawasaki, K. Senyo, Y. Nagashima, K. Yamamoto, K. Yamamura, T. Tsuboyama, J. Haba, H. Ikeda, H. Iwasaki, T. Matsuda, H. Ozaki, M. Tanaka, Y. Yamada, S. Okuno, S. Avrillon, Y. Asano, S. Mori, C. Fukunaga, T. Hirose, H. Miyata, K. Miyano, E. Banas, A. Bozek, Z. Natkaniec, H. Palka, M. Różańska, K. Rybicki","doi":"10.1109/NSSMIC.1995.504279","DOIUrl":null,"url":null,"abstract":"For the development of the silicon micro strip detector with the pitch of the readout strips as large as 250 /spl mu/m on ohmic side, we made samples with different structures. Charge collection was evaluated to optimize the width of implant strips, aluminum read-out strips, and/or the read-out scheme among strips.","PeriodicalId":409998,"journal":{"name":"1995 IEEE Nuclear Science Symposium and Medical Imaging Conference Record","volume":"52 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1995-10-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"1995 IEEE Nuclear Science Symposium and Medical Imaging Conference Record","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.1995.504279","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
Abstract
For the development of the silicon micro strip detector with the pitch of the readout strips as large as 250 /spl mu/m on ohmic side, we made samples with different structures. Charge collection was evaluated to optimize the width of implant strips, aluminum read-out strips, and/or the read-out scheme among strips.