{"title":"Harmonic Emissions in 0-9 kHz Frequency Range and Transient Effects in Grid-Connected Inverters Utilised in Solar Farms","authors":"J. Yaghoobi, Firuz Zare, Davood Solatialkaran","doi":"10.1109/ICHQP46026.2020.9177925","DOIUrl":null,"url":null,"abstract":"The penetration level of large-scale inverters utilized in solar farms is continuously increasing. A large part of PV power generation comes from large-scale and high-power inverters, which are normally connected to the grid through a distribution transformer. The operation of these high-power inverters with switching frequency mainly below 9 kHz due to design constrains need to be studied and their short-term incidents need to be understood. For that purpose, in this paper, output currents of three inverters have been measured using field measurements of a 3MW solar farm. The currents are then analyzed in time and frequency domains. The results show large short-term DC current and significant harmonic emissions (0-9 kHz) during short period of times, while the steady-state harmonic levels do not seem to be significant.","PeriodicalId":436720,"journal":{"name":"2020 19th International Conference on Harmonics and Quality of Power (ICHQP)","volume":"5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 19th International Conference on Harmonics and Quality of Power (ICHQP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHQP46026.2020.9177925","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
The penetration level of large-scale inverters utilized in solar farms is continuously increasing. A large part of PV power generation comes from large-scale and high-power inverters, which are normally connected to the grid through a distribution transformer. The operation of these high-power inverters with switching frequency mainly below 9 kHz due to design constrains need to be studied and their short-term incidents need to be understood. For that purpose, in this paper, output currents of three inverters have been measured using field measurements of a 3MW solar farm. The currents are then analyzed in time and frequency domains. The results show large short-term DC current and significant harmonic emissions (0-9 kHz) during short period of times, while the steady-state harmonic levels do not seem to be significant.