Selang Kepercayaan Bootstrap Parametrik untuk Perbedaan Signal to Noise Ratio dari Distribusi Eksponensial Dua Parameter pada Data Waktu Kegagalan Laminasi Mylar-Poliuretana
{"title":"Selang Kepercayaan Bootstrap Parametrik untuk Perbedaan Signal to Noise Ratio dari Distribusi Eksponensial Dua Parameter pada Data Waktu Kegagalan Laminasi Mylar-Poliuretana","authors":"Amirul Mukminin, Abdul Kudus","doi":"10.29313/bcss.v3i2.7627","DOIUrl":null,"url":null,"abstract":"Abstract. The two-parameter exponential distribution is a probability model associated with observed unit failure time data. Investigating the estimation characteristics of the Signal to Noise Ratio (SNR) difference between two populations with a two-parameter exponential distribution is intriguing. SNR represents the ratio between the mean and standard deviation. For more accurate results in estimating the SNR difference between two populations, confidence intervals can be utilized. One of the methods suitable for constructing confidence intervals is the parametric bootstrap method, particularly effective for small sample sizes with distribution assumptions. The confidence intervals built are based on bootstrap percentiles. The data used in this study consists of small-sized samples of failure times of mylar-polyurethane lamination in High Voltage Direct Current (HVDC) insulation structures, subjected to voltage loads of 100.3 kV/mm and 361.4 kV/mm. Based on the calculations, it was found that with a 95% confidence level, the parametric bootstrap confidence interval for the SNR difference of the two-parameter exponential distribution of failure times in mylar-polyurethane lamination under electric voltage loads of 100.3 kV/mm and 361.4 kV/mm falls within the range of [-0.29; 0.93]. \nAbstrak. Distribusi eksponensial dua parameter adalah model probabilitas yang terkait dengan data waktu kegagalan unit yang diamati. Karakteristik dari estimasi perbedaan Signal to Noise Ratio (SNR) dari dua populasi berdistribusi eksponensial dua parameter menarik untuk diteliti. SNR adalah rasio antara rata-rata dengan simpangan baku. Untuk hasil yang lebih akurat dalam memperkirakan estimasi perbedaan SNR dari dua populasi yaitu menggunakan selang kepercayaan. Salah satu metode yang dapat digunakan dalam membangun selang kepercayaan yaitu dengan metode bootstrap parametrik yang cocok untuk ukuran data sampel yang kecil dan memiliki asumsi distribusi. Selang kepercayaan yang dibangun didasarkan pada bootstrap persentil. Data yang digunakan adalah data sampel berukuran kecil yaitu waktu kegagalan laminasi mylar-poliuretana pada struktur isolasi High Voltage Direct Current (HVDC) dengan beban tegangan 100,3 kV/mm dan 361,4 kV/mm. Berdasarkan hasil perhitungan diperoleh bahwa dengan tingkat kepercayaan 95% selang kepercayaan bootstrap parametrik untuk perbedaan SNR dari distribusi eksponensial dua parameter pada data waktu kegagalan laminasi mylar-poliuretana dengan beban tegangan listrik 100,3 kV/mm dan 361,4 kV/mm adalah berada di dalam rentang [–0,29; 0,93].","PeriodicalId":337947,"journal":{"name":"Bandung Conference Series: Statistics","volume":"177 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-07-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bandung Conference Series: Statistics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.29313/bcss.v3i2.7627","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Abstract. The two-parameter exponential distribution is a probability model associated with observed unit failure time data. Investigating the estimation characteristics of the Signal to Noise Ratio (SNR) difference between two populations with a two-parameter exponential distribution is intriguing. SNR represents the ratio between the mean and standard deviation. For more accurate results in estimating the SNR difference between two populations, confidence intervals can be utilized. One of the methods suitable for constructing confidence intervals is the parametric bootstrap method, particularly effective for small sample sizes with distribution assumptions. The confidence intervals built are based on bootstrap percentiles. The data used in this study consists of small-sized samples of failure times of mylar-polyurethane lamination in High Voltage Direct Current (HVDC) insulation structures, subjected to voltage loads of 100.3 kV/mm and 361.4 kV/mm. Based on the calculations, it was found that with a 95% confidence level, the parametric bootstrap confidence interval for the SNR difference of the two-parameter exponential distribution of failure times in mylar-polyurethane lamination under electric voltage loads of 100.3 kV/mm and 361.4 kV/mm falls within the range of [-0.29; 0.93].
Abstrak. Distribusi eksponensial dua parameter adalah model probabilitas yang terkait dengan data waktu kegagalan unit yang diamati. Karakteristik dari estimasi perbedaan Signal to Noise Ratio (SNR) dari dua populasi berdistribusi eksponensial dua parameter menarik untuk diteliti. SNR adalah rasio antara rata-rata dengan simpangan baku. Untuk hasil yang lebih akurat dalam memperkirakan estimasi perbedaan SNR dari dua populasi yaitu menggunakan selang kepercayaan. Salah satu metode yang dapat digunakan dalam membangun selang kepercayaan yaitu dengan metode bootstrap parametrik yang cocok untuk ukuran data sampel yang kecil dan memiliki asumsi distribusi. Selang kepercayaan yang dibangun didasarkan pada bootstrap persentil. Data yang digunakan adalah data sampel berukuran kecil yaitu waktu kegagalan laminasi mylar-poliuretana pada struktur isolasi High Voltage Direct Current (HVDC) dengan beban tegangan 100,3 kV/mm dan 361,4 kV/mm. Berdasarkan hasil perhitungan diperoleh bahwa dengan tingkat kepercayaan 95% selang kepercayaan bootstrap parametrik untuk perbedaan SNR dari distribusi eksponensial dua parameter pada data waktu kegagalan laminasi mylar-poliuretana dengan beban tegangan listrik 100,3 kV/mm dan 361,4 kV/mm adalah berada di dalam rentang [–0,29; 0,93].
摘要双参数指数分布是与观测到的机组故障时间数据相关的概率模型。研究具有双参数指数分布的两个种群之间信噪比差的估计特性是一个有趣的问题。信噪比代表均值与标准差之比。为了更准确地估计两个种群之间的信噪比差异,可以使用置信区间。参数自举法是构造置信区间的一种方法,对具有分布假设的小样本量特别有效。建立的置信区间基于自举百分位数。本研究中使用的数据包括高压直流(HVDC)绝缘结构中聚酯聚氨酯层合材料在100.3 kV/mm和361.4 kV/mm电压载荷作用下失效次数的小样本。计算结果表明:在95%置信水平下,100.3 kV/mm和361.4 kV/mm电压载荷下,聚酯-聚氨酯复合材料失效次数双参数指数分布信噪比差的参数自举置信区间在[-0.29];0.93]。Abstrak。分布-自发双参数adalah模型概率是杨terkai邓根数据waktu kegagalan单位杨diamati。Karakteristik达里估计、信噪比(SNR)达里估计、普遍分布达里估计、随机参数达里估计。信噪比数据分析:数据分析,数据分析,数据分析,数据分析。Untuk hasil yang lebih akurat dalam成员perkirakan estimasi perbedaan和SNR dari dua populasi yitu menggunakan selang keperayan。Salah satu方法yang dapat digunakan dalam membangunan selang keperayaan yitu dengan方法自举参数yang cocok untuk ukuran数据样本yang kecil dan memiliki假设分布。Selang keperayaan yang dibangun didasarkan pada bootstrap。数据yang digunakan adalah数据样本berukuran kecil yitu waktu kegagalan laminasi mylar-poliuretana pada struktor isolasi高压直流(HVDC) dengan beban tegangan 100,3 kV/mm但361,4 kV/mm。Berdasarkan hasil perhitungan diperoleh bahwa kepercayaan和95% selang kepercayaan自举参数化untuk perbedaan和信噪比分布,自发双参数化数据waktu kegagalan laminasi -poliuretana dengan beban tegangan listrik 100,3 kV/mm和361,4 kV/mm adalah berada di dalam rentang [0,29];0, 93]。