Carbon-aware routing in software defined inter data center network

Deepshikha Singh, G. Chandwani
{"title":"Carbon-aware routing in software defined inter data center network","authors":"Deepshikha Singh, G. Chandwani","doi":"10.1109/ANTS.2015.7413640","DOIUrl":null,"url":null,"abstract":"Data center operators are trying to reduce environmental cost (carbon emission), by establishing data centers at locations where renewable energy (wind or solar energy) is available. To maximize the use of renewable energy the connection-request is routed to these “Green” data centers rather than “Brown” data centers (powered by hydrocarbon energy), subject to content availability, latency to the end-host and load at that data center. However availability of renewable energy varies throughout the day and is subjected to weather conditions. Such carbon-aware routing require the global knowledge of renewable energy availability at green data centers in the network. Centralized control can help in optimizing network-wide energy use. This paper investigates the effect of carbon-aware routing in OpenFlow based software defined inter-data center optical-network (wherein some data centers powered by green energy), on energy cost, energy consumption and carbon emission in the network. Green Data centers have higher energy cost compared to brown data centers as production of green energy is costly compared to brown energy. We propose priority-based carbon-aware routing scheme and compare its performance in terms of energy cost and carbon emission with two scheme namely Nearest and Green. Numerical results obtained from simulation show that priority-based carbon-aware routing is optimum (with assumed emission factor and energy cost), in terms of trade-off between carbon emission and energy cost, when compared with other two routing schemes.","PeriodicalId":347920,"journal":{"name":"2015 IEEE International Conference on Advanced Networks and Telecommuncations Systems (ANTS)","volume":"18 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE International Conference on Advanced Networks and Telecommuncations Systems (ANTS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ANTS.2015.7413640","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

Data center operators are trying to reduce environmental cost (carbon emission), by establishing data centers at locations where renewable energy (wind or solar energy) is available. To maximize the use of renewable energy the connection-request is routed to these “Green” data centers rather than “Brown” data centers (powered by hydrocarbon energy), subject to content availability, latency to the end-host and load at that data center. However availability of renewable energy varies throughout the day and is subjected to weather conditions. Such carbon-aware routing require the global knowledge of renewable energy availability at green data centers in the network. Centralized control can help in optimizing network-wide energy use. This paper investigates the effect of carbon-aware routing in OpenFlow based software defined inter-data center optical-network (wherein some data centers powered by green energy), on energy cost, energy consumption and carbon emission in the network. Green Data centers have higher energy cost compared to brown data centers as production of green energy is costly compared to brown energy. We propose priority-based carbon-aware routing scheme and compare its performance in terms of energy cost and carbon emission with two scheme namely Nearest and Green. Numerical results obtained from simulation show that priority-based carbon-aware routing is optimum (with assumed emission factor and energy cost), in terms of trade-off between carbon emission and energy cost, when compared with other two routing schemes.
软件定义跨数据中心网络中的碳感知路由
数据中心运营商正试图通过在可再生能源(风能或太阳能)可用的地方建立数据中心来降低环境成本(碳排放)。为了最大限度地利用可再生能源,连接请求被路由到这些“绿色”数据中心,而不是“棕色”数据中心(由碳氢化合物能源供电),这取决于内容可用性、对终端主机的延迟以及该数据中心的负载。然而,可再生能源的可用性全天变化,并受到天气条件的影响。这种对碳敏感的路由需要网络中绿色数据中心的可再生能源可用性的全球知识。集中控制有助于优化整个网络的能源使用。本文研究了基于OpenFlow的软件定义数据中心间光网络(其中一些数据中心由绿色能源供电)中碳感知路由对网络中能源成本、能源消耗和碳排放的影响。与棕色数据中心相比,绿色数据中心的能源成本更高,因为绿色能源的生产成本高于棕色能源。提出了基于优先级的碳感知路由方案,并将其与Nearest和Green两种方案在能源成本和碳排放方面的性能进行了比较。仿真结果表明,在假设排放因子和能源成本的情况下,基于优先级的碳感知路由方案在碳排放和能源成本的权衡方面优于其他两种路由方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信