{"title":"Call admission control in mobile cellular systems using fuzzy associative memory","authors":"Sivaramakrishna Mopati, D. Sarkar","doi":"10.1109/ICCCN.2003.1284155","DOIUrl":null,"url":null,"abstract":"In a mobile cellular system quality of service to mobile terminals (MTs) is measured by the probability of new call blocking P/sub b/, and the probability of forced termination, P/sub ft/. Since the available bandwidth in a cell is very limited, both P/sub b/ and P/sub ft/ cannot be reduced or avoided simultaneously. Usually keeping the P/sub ft/ below a designated level is accepted as the measure of quality of service. Admission of new calls is controlled to reduce P/sub ft/. However, there are at least three parameters (new call arrival rate, mean duration of calls, and mobility of users) that can and change dynamically. Moreover, these parameters are related with P/sub ft/ via complicated nonlinear equations. Therefore, call admission control (CAC) for maintaining a desired value of P/sub ft/ is a very challenging task. No CAC algorithm has been reported in the past that can function well with dynamic changes to all these three parameters. We proposed an algorithm that addresses this issue. The new algorithm uses a fuzzy controller to adjust the call preblocking load value with the changing traffic parameters. The fuzzy controller makes use of fuzzy associative memory (FAM) to maintain the required QoS. The use of new system in dynamic traffic conditions is illustrated. Providing the required level of QoS, the algorithm also increases the channel utilization. The proposed CAC with FAM is compared and contrasted with previous CACs.","PeriodicalId":168378,"journal":{"name":"Proceedings. 12th International Conference on Computer Communications and Networks (IEEE Cat. No.03EX712)","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings. 12th International Conference on Computer Communications and Networks (IEEE Cat. No.03EX712)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICCCN.2003.1284155","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

Abstract

In a mobile cellular system quality of service to mobile terminals (MTs) is measured by the probability of new call blocking P/sub b/, and the probability of forced termination, P/sub ft/. Since the available bandwidth in a cell is very limited, both P/sub b/ and P/sub ft/ cannot be reduced or avoided simultaneously. Usually keeping the P/sub ft/ below a designated level is accepted as the measure of quality of service. Admission of new calls is controlled to reduce P/sub ft/. However, there are at least three parameters (new call arrival rate, mean duration of calls, and mobility of users) that can and change dynamically. Moreover, these parameters are related with P/sub ft/ via complicated nonlinear equations. Therefore, call admission control (CAC) for maintaining a desired value of P/sub ft/ is a very challenging task. No CAC algorithm has been reported in the past that can function well with dynamic changes to all these three parameters. We proposed an algorithm that addresses this issue. The new algorithm uses a fuzzy controller to adjust the call preblocking load value with the changing traffic parameters. The fuzzy controller makes use of fuzzy associative memory (FAM) to maintain the required QoS. The use of new system in dynamic traffic conditions is illustrated. Providing the required level of QoS, the algorithm also increases the channel utilization. The proposed CAC with FAM is compared and contrasted with previous CACs.
基于模糊联想记忆的移动蜂窝系统呼叫接纳控制
在移动蜂窝系统中,对移动终端的服务质量由新呼叫阻塞概率P/sub b/和强制终止概率P/sub ft/来衡量。由于小区中的可用带宽非常有限,因此不能同时降低或避免P/sub b/和P/sub ft/。通常,将P/sub / ft/保持在指定的水平以下被接受为服务质量的衡量标准。控制新呼叫的准入,以减少P/sub /。但是,至少有三个参数(新呼叫到达率、平均呼叫持续时间和用户的移动性)可以动态更改。此外,这些参数通过复杂的非线性方程与P/ ft/相关。因此,为了保持P/sub / ft/的理想值,呼叫允许控制(CAC)是一项非常具有挑战性的任务。在过去的报道中,没有CAC算法可以在这三个参数的动态变化下很好地工作。我们提出了一个算法来解决这个问题。该算法利用模糊控制器根据话务参数的变化来调整呼叫预阻塞负载值。模糊控制器利用模糊关联记忆(FAM)来维持所需的QoS。说明了新系统在动态交通条件下的应用。在提供所需的QoS水平的同时,该算法还提高了信道利用率。提出的带FAM的CAC与以前的CAC进行了比较和对比。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信