Operation and control of wind driven isolated asynchronous generator with a battery and a zigzag transformer

S. Sharma, Bhim Singh
{"title":"Operation and control of wind driven isolated asynchronous generator with a battery and a zigzag transformer","authors":"S. Sharma, Bhim Singh","doi":"10.1109/INDCON.2010.5712727","DOIUrl":null,"url":null,"abstract":"This work deals with the operation and control of a wind turbine driven isolated asynchronous generator (IAG) system to feed three-phase four-wire consumer loads. The voltage and frequency controller (VFC) of IAG consists of a three-leg voltage sourced converter (VSC) and a battery energy storage system. A zig-zag transformer is used to provide the neutral terminal for three-phase four wire consumer loads and to reduce the rating of the VSC. An instantaneous reactive power theory (IRPT) is implemented for the derivation of reference source currents using a DSP. The performance of VFC of IAG is demonstrated through extensive test results.","PeriodicalId":109071,"journal":{"name":"2010 Annual IEEE India Conference (INDICON)","volume":"34 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 Annual IEEE India Conference (INDICON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/INDCON.2010.5712727","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

This work deals with the operation and control of a wind turbine driven isolated asynchronous generator (IAG) system to feed three-phase four-wire consumer loads. The voltage and frequency controller (VFC) of IAG consists of a three-leg voltage sourced converter (VSC) and a battery energy storage system. A zig-zag transformer is used to provide the neutral terminal for three-phase four wire consumer loads and to reduce the rating of the VSC. An instantaneous reactive power theory (IRPT) is implemented for the derivation of reference source currents using a DSP. The performance of VFC of IAG is demonstrated through extensive test results.
带电池和锯齿形变压器的风力隔离异步发电机的运行与控制
本文研究了风力发电机驱动的隔离异步发电机(IAG)系统的运行和控制,以馈电三相四线制用户负载。IAG的电压频率控制器(VFC)由三支路电压源变换器(VSC)和电池储能系统组成。锯齿形变压器用于为三相四线消费负载提供中性点端子,并降低VSC的额定值。利用DSP实现了参考源电流的瞬时无功理论(IRPT)推导。通过大量的测试结果证明了IAG的VFC性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信