Phantom setup for precise perfusion measurement by microwave

M. Tofighi, Jayendrasingh R. Pardeshi, Eric Wasatonic
{"title":"Phantom setup for precise perfusion measurement by microwave","authors":"M. Tofighi, Jayendrasingh R. Pardeshi, Eric Wasatonic","doi":"10.1109/BIOWIRELESS.2016.7445566","DOIUrl":null,"url":null,"abstract":"Toward the objective of using microwave methods to measure blood perfusion, a setup is constructed to obtain thermal washout curves after microwave heating. The setup features an omnidirectional flow in a porous medium irradiated by microwave power. Flow levels in the range of 0-5 mL/min can be precisely set. Such small flow levels realistically correspond to the blood perfusion within tissues. The medium's temperature is raised by 0.2 °C, through irradiating 1.1 W at 900 MHz. Results indicate that small flow levels could be distinctly differentiated by the thermal decay curve. However, the observed heating depth extending beyond 2 cm indicates that higher frequencies may be necessary for shallower perfusion measurements (e.g. in skin).","PeriodicalId":154090,"journal":{"name":"2016 IEEE Topical Conference on Biomedical Wireless Technologies, Networks, and Sensing Systems (BioWireleSS)","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-04-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE Topical Conference on Biomedical Wireless Technologies, Networks, and Sensing Systems (BioWireleSS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BIOWIRELESS.2016.7445566","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Toward the objective of using microwave methods to measure blood perfusion, a setup is constructed to obtain thermal washout curves after microwave heating. The setup features an omnidirectional flow in a porous medium irradiated by microwave power. Flow levels in the range of 0-5 mL/min can be precisely set. Such small flow levels realistically correspond to the blood perfusion within tissues. The medium's temperature is raised by 0.2 °C, through irradiating 1.1 W at 900 MHz. Results indicate that small flow levels could be distinctly differentiated by the thermal decay curve. However, the observed heating depth extending beyond 2 cm indicates that higher frequencies may be necessary for shallower perfusion measurements (e.g. in skin).
幻影装置用于精确的微波灌注测量
为了利用微波方法测量血液灌注,建立了微波加热后的热冲洗曲线。该装置的特点是在微波功率照射下多孔介质中的全向流动。在0-5毫升/分钟范围内的流量水平可以精确设置。如此小的血流水平实际上对应于组织内的血液灌注。通过在900 MHz下照射1.1 W,介质温度升高0.2°C。结果表明,热衰减曲线能明显区分小流量。然而,观察到的加热深度超过2厘米表明,对于较浅的灌注测量(例如在皮肤中)可能需要更高的频率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信