G. Carini, S. Boutet, M. Chollet, A. Dragone, G. Haller, P. Hart, S. Herrmann, C. Kenney, J. Koglin, H. Lemke, M. Messerschmidt, S. Nelson, J. Pines, A. Robert, S. Song, J. Thayer, G. Williams, D. Zhu
{"title":"Measurements at synchrotrons and FELs: Some differences observed with the CSPAD","authors":"G. Carini, S. Boutet, M. Chollet, A. Dragone, G. Haller, P. Hart, S. Herrmann, C. Kenney, J. Koglin, H. Lemke, M. Messerschmidt, S. Nelson, J. Pines, A. Robert, S. Song, J. Thayer, G. Williams, D. Zhu","doi":"10.1109/NSSMIC.2013.6829694","DOIUrl":null,"url":null,"abstract":"A series of measurements to validate the performance of the CSPAD were performed at the Stanford Synchrotron Radiation Lightsource (SSRL) and at the Linac Coherent Light Source (LCLS). These were important steps to complete the development of the detector, characterize its behavior under typical experimental conditions, and implement calibration procedures. In this paper we report differences observed in the response of the CSPAD to these very different sources. Particularly the linearity at very high fluence was investigated with correlation plots and weighting-function response.","PeriodicalId":246351,"journal":{"name":"2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC)","volume":"80 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2013.6829694","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
A series of measurements to validate the performance of the CSPAD were performed at the Stanford Synchrotron Radiation Lightsource (SSRL) and at the Linac Coherent Light Source (LCLS). These were important steps to complete the development of the detector, characterize its behavior under typical experimental conditions, and implement calibration procedures. In this paper we report differences observed in the response of the CSPAD to these very different sources. Particularly the linearity at very high fluence was investigated with correlation plots and weighting-function response.