D. Farley, A. Dasgupta, Y. Zhou, J. Caers, J. D. de Vries
{"title":"Fatigue model based on average cross-section strain of Cu trace cyclic bending","authors":"D. Farley, A. Dasgupta, Y. Zhou, J. Caers, J. D. de Vries","doi":"10.1109/ESIME.2011.5765858","DOIUrl":null,"url":null,"abstract":"This study focuses on quasi-static mechanical cycling durability of copper traces on printed wiring assemblies (PWAs). PWA specimens populated with Land Grid Array (LGA) components on copper-defined pads were cycled to failure under zero-to-max, three-point bending. Failure is defined in terms of electrical opens due to fatigue damage propagation through the entire cross-section of the trace. Failure statistics were collected and failure analysis was conducted to identify fatigue failures in the copper traces, near the connection to the solder pad.","PeriodicalId":115489,"journal":{"name":"2011 12th Intl. Conf. on Thermal, Mechanical & Multi-Physics Simulation and Experiments in Microelectronics and Microsystems","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-04-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 12th Intl. Conf. on Thermal, Mechanical & Multi-Physics Simulation and Experiments in Microelectronics and Microsystems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ESIME.2011.5765858","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
Abstract
This study focuses on quasi-static mechanical cycling durability of copper traces on printed wiring assemblies (PWAs). PWA specimens populated with Land Grid Array (LGA) components on copper-defined pads were cycled to failure under zero-to-max, three-point bending. Failure is defined in terms of electrical opens due to fatigue damage propagation through the entire cross-section of the trace. Failure statistics were collected and failure analysis was conducted to identify fatigue failures in the copper traces, near the connection to the solder pad.