Validity, reliability and measurement error of quadriceps femoris muscle thickness obtained by ultrasound in healthy adults: a systematic review

André Luiz Conveniente Soares, Ramon Franco Carvalho, Roberto Mogami, C. Meirelles, Paulo Sergio Chagas Gomes
{"title":"Validity, reliability and measurement error of quadriceps femoris muscle thickness obtained by ultrasound in healthy adults: a systematic review","authors":"André Luiz Conveniente Soares, Ramon Franco Carvalho, Roberto Mogami, C. Meirelles, Paulo Sergio Chagas Gomes","doi":"10.1590/1980-0037.2023v25e93936","DOIUrl":null,"url":null,"abstract":"Abstract Due to its low cost and operational simplicity, ultrasound has been used to monitor muscle thickness in laboratory environments, rehabilitation clinics, and sports clubs. However, it is necessary to determine the measurement's quality to infer whether the possible changes observed are derived from the treatment or the measurement error. Therefore, we performed a systematic review to determine the validity, reliability, and measurement error of quadriceps femoris muscle thickness obtained by ultrasound in healthy adults. A search was conducted in the Pubmed, Scopus, and Web of Science databases until April 2022. The study selection process was carried out by two independent researchers, with the presence of a third researcher in case of disagreements. Twenty-six studies were eligible for the review, being 4 of validity, 4 of reliability only, and 18 of reliability and measurement error. The intraclass correlation coefficient ranged from 0.60 to 0.99 in validity studies and from 0.44 to 0.99 in reliability studies. The typical error of measurement ranged from 0.01 to 0.47 cm, and the coefficient of variation was from 0.5 to 17.9%. Four studies received “very good” classification in all the risk of bias analysis criteria. Therefore, it is concluded that the quadriceps femoris muscle thickness obtained by ultrasound was shown to be valid, reliable, and to have low measurement errors in healthy adults. The weighted average of the relative error was 6.5%, less than typical increases in resistance training studies. The raters' experience and methodological care for repeated measurements were necessary to observe low measurement errors.","PeriodicalId":106840,"journal":{"name":"Revista Brasileira de Cineantropometria & Desempenho Humano","volume":"16 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista Brasileira de Cineantropometria & Desempenho Humano","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1590/1980-0037.2023v25e93936","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract Due to its low cost and operational simplicity, ultrasound has been used to monitor muscle thickness in laboratory environments, rehabilitation clinics, and sports clubs. However, it is necessary to determine the measurement's quality to infer whether the possible changes observed are derived from the treatment or the measurement error. Therefore, we performed a systematic review to determine the validity, reliability, and measurement error of quadriceps femoris muscle thickness obtained by ultrasound in healthy adults. A search was conducted in the Pubmed, Scopus, and Web of Science databases until April 2022. The study selection process was carried out by two independent researchers, with the presence of a third researcher in case of disagreements. Twenty-six studies were eligible for the review, being 4 of validity, 4 of reliability only, and 18 of reliability and measurement error. The intraclass correlation coefficient ranged from 0.60 to 0.99 in validity studies and from 0.44 to 0.99 in reliability studies. The typical error of measurement ranged from 0.01 to 0.47 cm, and the coefficient of variation was from 0.5 to 17.9%. Four studies received “very good” classification in all the risk of bias analysis criteria. Therefore, it is concluded that the quadriceps femoris muscle thickness obtained by ultrasound was shown to be valid, reliable, and to have low measurement errors in healthy adults. The weighted average of the relative error was 6.5%, less than typical increases in resistance training studies. The raters' experience and methodological care for repeated measurements were necessary to observe low measurement errors.
健康成人超声测量股四头肌厚度的效度、信度和测量误差:系统综述
由于其成本低、操作简单,超声已被用于实验室环境、康复诊所和体育俱乐部的肌肉厚度监测。然而,有必要确定测量的质量,以推断观察到的可能变化是来自处理还是测量误差。因此,我们进行了一项系统综述,以确定超声获得的健康成人股四头肌厚度的有效性、可靠性和测量误差。在Pubmed, Scopus和Web of Science数据库中进行了搜索,直到2022年4月。研究选择过程由两名独立的研究人员进行,在出现分歧的情况下,第三名研究人员在场。26项研究符合评价标准,其中4项为效度研究,4项仅为信度研究,18项为信度和测量误差研究。效度研究的类内相关系数为0.60 ~ 0.99,信度研究的类内相关系数为0.44 ~ 0.99。典型测量误差范围为0.01 ~ 0.47 cm,变异系数为0.5 ~ 17.9%。四项研究在所有偏倚风险分析标准中获得“非常好”分类。因此,超声获得的股四头肌厚度在健康成人中是有效、可靠的,测量误差小。相对误差的加权平均值为6.5%,低于阻力训练研究中的典型增幅。评分员的经验和对重复测量的方法学上的注意是观察到低测量误差所必需的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信