Neutron-induced failure tests of 3300-V IGBTs for the Spallation Neutron Source accelerator

D. Borovina, J. Bradley, M. Pieck, R. Przeklasa, T. Hardek, M. Lynch, D. Rees, P. Tallerico, W. Reass, S. Wender, B. Takala, S. Ruggles
{"title":"Neutron-induced failure tests of 3300-V IGBTs for the Spallation Neutron Source accelerator","authors":"D. Borovina, J. Bradley, M. Pieck, R. Przeklasa, T. Hardek, M. Lynch, D. Rees, P. Tallerico, W. Reass, S. Wender, B. Takala, S. Ruggles","doi":"10.1109/PAC.2003.1289641","DOIUrl":null,"url":null,"abstract":"The RF transmitters for the 1-GeV Spallation Neutron Source (SNS) linear accelerator are powered by 15 converter-modulator stations. Each converter-modulator provides pulses up to 11 MW peak power with a 1.1 MW average power to a multiple-klystron load. A low-voltage switching network, comprised of three sets of four IGBTs in an 'H-bridge' configuration, is used to generate the 20 kHz drive waveform components for the three step-up transformer primaries. This setup brings the total number of 3300-volt semiconductor IGBTs operating within the accelerator at 180. When biased to operating voltages of 1500 V or greater, all IGBTs are inherently sensitive to neutron interactions caused by background cosmic ray radiation. The project described used neutrons produced by proton spallation (with a similar spectrum as cosmic ray neutrons) to gain knowledge of failure mechanisms of the SNS IGBTs. These tests were performed using the highly accelerated neutron flux generated at the Weapons Neutron Research facility at the Los Alamos National Laboratory. The results of these experiments have shown the existence of a critical threshold voltage that lies within the operational range beyond which the IGBTs are no longer effective. This threshold varied with each brand of IGBT tested. Statistical failure times have also been projected for all brands of IGBT tested under normal biased operation with the SNS accelerator given natural neutron flux in Oak Ridge, TN.","PeriodicalId":419488,"journal":{"name":"Proceedings of the 2003 Particle Accelerator Conference","volume":"126 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-05-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 2003 Particle Accelerator Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PAC.2003.1289641","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

The RF transmitters for the 1-GeV Spallation Neutron Source (SNS) linear accelerator are powered by 15 converter-modulator stations. Each converter-modulator provides pulses up to 11 MW peak power with a 1.1 MW average power to a multiple-klystron load. A low-voltage switching network, comprised of three sets of four IGBTs in an 'H-bridge' configuration, is used to generate the 20 kHz drive waveform components for the three step-up transformer primaries. This setup brings the total number of 3300-volt semiconductor IGBTs operating within the accelerator at 180. When biased to operating voltages of 1500 V or greater, all IGBTs are inherently sensitive to neutron interactions caused by background cosmic ray radiation. The project described used neutrons produced by proton spallation (with a similar spectrum as cosmic ray neutrons) to gain knowledge of failure mechanisms of the SNS IGBTs. These tests were performed using the highly accelerated neutron flux generated at the Weapons Neutron Research facility at the Los Alamos National Laboratory. The results of these experiments have shown the existence of a critical threshold voltage that lies within the operational range beyond which the IGBTs are no longer effective. This threshold varied with each brand of IGBT tested. Statistical failure times have also been projected for all brands of IGBT tested under normal biased operation with the SNS accelerator given natural neutron flux in Oak Ridge, TN.
散裂中子源加速器3300-V igbt中子诱导失效试验
用于1-GeV散裂中子源(SNS)直线加速器的射频发射机由15个转换调制器站供电。每个变换器-调制器为多速调管负载提供高达11 MW峰值功率和1.1 MW平均功率的脉冲。低压开关网络由三组“h桥”配置的四个igbt组成,用于为三个升压变压器初级产生20khz驱动波形分量。这种设置使在加速器内工作的3300伏半导体igbt总数达到180个。当偏置到1500v或更高的工作电压时,所有igbt都对背景宇宙射线辐射引起的中子相互作用敏感。该项目描述了利用质子散裂产生的中子(具有与宇宙射线中子相似的光谱)来了解SNS igbt的失效机制。这些试验是利用洛斯阿拉莫斯国家实验室武器中子研究设施产生的高加速中子通量进行的。这些实验的结果表明,存在一个临界阈值电压,该电压位于igbt不再有效的工作范围内。这个阈值随测试的IGBT品牌不同而不同。统计失效时间也预测了所有品牌的IGBT在正常偏压操作下使用SNS加速器在田纳西州橡树岭天然中子通量下测试的统计失效时间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书