Experimental analysis for plate-type electrostatic precipitators with three sections

G. Popa, S. Deaconu, I. Popa, C. Diniș
{"title":"Experimental analysis for plate-type electrostatic precipitators with three sections","authors":"G. Popa, S. Deaconu, I. Popa, C. Diniș","doi":"10.1109/OPTIM.2012.6231779","DOIUrl":null,"url":null,"abstract":"The plate-type electrostatic precipitators have been use by industry applications as the preferred method for controlling pollution with dust particles. This article is presenting an experimental analysis of the current-voltage characteristics, dust emissions and powers absorbed by the sources of some three-section electrostatic precipitators from a thermo-electrical power plant. Due to complex phenomena, at industrial electrostatic precipitators the current-voltage characteristics from the sections are permanently modifying, which makes impossible the mathematic modelling. It was not noticed a mathematical connection between the evolution of the dust emissions and powers absorbed by the supply sources.","PeriodicalId":382406,"journal":{"name":"2012 13th International Conference on Optimization of Electrical and Electronic Equipment (OPTIM)","volume":"24 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-05-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 13th International Conference on Optimization of Electrical and Electronic Equipment (OPTIM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/OPTIM.2012.6231779","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

The plate-type electrostatic precipitators have been use by industry applications as the preferred method for controlling pollution with dust particles. This article is presenting an experimental analysis of the current-voltage characteristics, dust emissions and powers absorbed by the sources of some three-section electrostatic precipitators from a thermo-electrical power plant. Due to complex phenomena, at industrial electrostatic precipitators the current-voltage characteristics from the sections are permanently modifying, which makes impossible the mathematic modelling. It was not noticed a mathematical connection between the evolution of the dust emissions and powers absorbed by the supply sources.
三段板式静电除尘器的实验分析
板式静电除尘器已被工业应用作为控制粉尘污染的首选方法。本文对某热电厂三段静电除尘器的电流电压特性、排尘量及源吸收功率进行了实验分析。在工业静电除尘器中,由于现象复杂,各截面的电流-电压特性是不断变化的,这使得数学建模变得不可能。人们没有注意到粉尘排放的演变与电源所吸收的功率之间的数学联系。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信