{"title":"A Cost-Effective High-Performance Conducted Emission Test Solution to Comply with MIL-STD-461F/G Standard","authors":"Nam Nguyen-Tat, Luong Nguyen-Xuan, Thanh Nguyen","doi":"10.1109/NICS54270.2021.9701470","DOIUrl":null,"url":null,"abstract":"The TDK’s MIL-STD-461F/G CE102-comp1iant test is a semi-automatic solution using the leading edge standards-compliant MXE EMI test receiver Keysight N9038A and the authorized TDK®Emission Labs 9.68 software package. This however still results in longer measuring time and inferior measuring performance. Hence, a novel fully automatic test scheme in accordance with control software integrating suitable compensation algorithms is proposed to surmount these disadvantages. The proposal though uses less advanced models such as the low-cost X-Series N9000A CXA, or the high-performance X-Series N9030A PXA Keysight signal analyzers yet creates higher measuring performance in a shorter time. The test configuration with related problems are investigated and resolved then the experimental results are presented to compare with that of the TDK’s solution showing the proposal’s advantages.","PeriodicalId":296963,"journal":{"name":"2021 8th NAFOSTED Conference on Information and Computer Science (NICS)","volume":"24 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-12-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 8th NAFOSTED Conference on Information and Computer Science (NICS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NICS54270.2021.9701470","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The TDK’s MIL-STD-461F/G CE102-comp1iant test is a semi-automatic solution using the leading edge standards-compliant MXE EMI test receiver Keysight N9038A and the authorized TDK®Emission Labs 9.68 software package. This however still results in longer measuring time and inferior measuring performance. Hence, a novel fully automatic test scheme in accordance with control software integrating suitable compensation algorithms is proposed to surmount these disadvantages. The proposal though uses less advanced models such as the low-cost X-Series N9000A CXA, or the high-performance X-Series N9030A PXA Keysight signal analyzers yet creates higher measuring performance in a shorter time. The test configuration with related problems are investigated and resolved then the experimental results are presented to compare with that of the TDK’s solution showing the proposal’s advantages.
符合MIL-STD-461F/G标准的高性价比高性能传导辐射测试解决方案
TDK的MIL-STD-461F/G ce102兼容测试是一种半自动解决方案,使用符合领先标准的MXE EMI测试接收器Keysight N9038A和授权的TDK®Emission Labs 9.68软件包。然而,这仍然导致了较长的测量时间和较差的测量性能。为了克服这些缺点,提出了一种基于控制软件的综合补偿算法的全自动测试方案。该方案虽然使用了低成本的x系列N9000A CXA或高性能的x系列N9030A PXA等不太先进的型号,但在更短的时间内创造了更高的测量性能。对测试配置中存在的相关问题进行了研究和解决,并给出了实验结果,与TDK方案进行了比较,显示了该方案的优势。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信