Optimal location for shunt connected reactive power compensation

A. Elansari, J. Burr, S. Finney, M. Edrah
{"title":"Optimal location for shunt connected reactive power compensation","authors":"A. Elansari, J. Burr, S. Finney, M. Edrah","doi":"10.1109/UPEC.2014.6934743","DOIUrl":null,"url":null,"abstract":"Flexible AC Transmission Systems (FACTS) have been used to improve voltage stability and to increase Total Transfer Capability (TTC) of transmission systems. Shunt injected reactive power compensation such as Mechanically Switched Capacitors (MSC), Static VAr Compensators (SVC) and Static Synchronous Compensators (STATCOM) are widely used as practical and cost effective solutions to improve transmission line performance. This paper illustrates a new approach to determine optimal location for VAr shunt compensation as a measure to maintain system voltages within acceptable levels which leads to losses reduction, increased system utilization and improved stability. This paper introduces a new method to determine optimal location for shunt compensator devices considering both economic and security aspects. The Kundur two area test system is used to evaluate and validate the new algorithm using NEPLAN power system analysis tool. The results show the effectiveness of the new method to determine the optimal location for shunt VAr compensation.","PeriodicalId":414838,"journal":{"name":"2014 49th International Universities Power Engineering Conference (UPEC)","volume":"41 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-10-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 49th International Universities Power Engineering Conference (UPEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/UPEC.2014.6934743","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

Abstract

Flexible AC Transmission Systems (FACTS) have been used to improve voltage stability and to increase Total Transfer Capability (TTC) of transmission systems. Shunt injected reactive power compensation such as Mechanically Switched Capacitors (MSC), Static VAr Compensators (SVC) and Static Synchronous Compensators (STATCOM) are widely used as practical and cost effective solutions to improve transmission line performance. This paper illustrates a new approach to determine optimal location for VAr shunt compensation as a measure to maintain system voltages within acceptable levels which leads to losses reduction, increased system utilization and improved stability. This paper introduces a new method to determine optimal location for shunt compensator devices considering both economic and security aspects. The Kundur two area test system is used to evaluate and validate the new algorithm using NEPLAN power system analysis tool. The results show the effectiveness of the new method to determine the optimal location for shunt VAr compensation.
并联无功补偿的最佳位置
柔性交流输电系统(FACTS)已被用于改善电压稳定性和提高输电系统的总传输能力(TTC)。并联注入无功补偿,如机械开关电容器(MSC)、静态无功补偿器(SVC)和静态同步补偿器(STATCOM),作为提高输电线路性能的实用和经济有效的解决方案被广泛应用。本文阐述了一种确定无功并联补偿的最佳位置的新方法,作为一种将系统电压维持在可接受水平内的措施,从而减少损耗,提高系统利用率和提高稳定性。本文介绍了一种从经济性和安全性两方面考虑,确定并联补偿装置最优位置的新方法。利用NEPLAN电力系统分析工具,利用Kundur二区测试系统对新算法进行了评估和验证。结果表明,该方法可以有效地确定并联无功补偿的最佳位置。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信