Using of dosimetric film for analysis of energy density distribution of a high-current pulsed electron beam

V. V. Ezhov, D. Goncharov, A. I. Pushkarev, G. Remnev, J.A. Mikicha
{"title":"Using of dosimetric film for analysis of energy density distribution of a high-current pulsed electron beam","authors":"V. V. Ezhov, D. Goncharov, A. I. Pushkarev, G. Remnev, J.A. Mikicha","doi":"10.1109/KORUS.2005.1507666","DOIUrl":null,"url":null,"abstract":"Technique of measurement energy density of high-current electron beam by means of dosimetric field of POR type (5-50 kGy) and standard scanner is presented. Also is shown that relative optical density of the film increases linear to increasing of absorbed dose in the range of absorbed dose 5-120 kGy. Correlation dependence of digital image parameter \"light\" of irradiated samples of dosimetric film on samples relative optical density is obtained. By means of correlation function, two-dimensional matrix of absorbed dose's values, corresponding with electron beam autograph on dosimetric film is derived. Elaborated technique allows to measure nonuniformity of energy density of pulsed electron beam with spatial definition less than 1 mm during the measurement of absolute values of energy density.","PeriodicalId":112535,"journal":{"name":"Proceedings. The 9th Russian-Korean International Symposium on Science and Technology, 2005. KORUS 2005.","volume":"76 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2005-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings. The 9th Russian-Korean International Symposium on Science and Technology, 2005. KORUS 2005.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/KORUS.2005.1507666","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Technique of measurement energy density of high-current electron beam by means of dosimetric field of POR type (5-50 kGy) and standard scanner is presented. Also is shown that relative optical density of the film increases linear to increasing of absorbed dose in the range of absorbed dose 5-120 kGy. Correlation dependence of digital image parameter "light" of irradiated samples of dosimetric film on samples relative optical density is obtained. By means of correlation function, two-dimensional matrix of absorbed dose's values, corresponding with electron beam autograph on dosimetric film is derived. Elaborated technique allows to measure nonuniformity of energy density of pulsed electron beam with spatial definition less than 1 mm during the measurement of absolute values of energy density.
用剂量学薄膜分析大电流脉冲电子束的能量密度分布
介绍了用POR型剂量场(5 ~ 50 kGy)和标准扫描仪测量大电流电子束能量密度的技术。在吸收剂量5 ~ 120kgy范围内,膜的相对光密度随吸收剂量的增加呈线性增加。得到了剂量测定膜辐照样品的数字图像参数“光”与样品相对光密度的相关关系。利用相关函数,导出了与剂量测定膜上电子束签名相对应的吸收剂量值的二维矩阵。该技术可以在测量能量密度绝对值的过程中测量脉冲电子束能量密度的非均匀性,其空间清晰度小于1mm。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书