Informativeness assessment of the laser scanning results at the verticality study of the energy objects heat pipes

{"title":"Informativeness assessment of the laser scanning results at the verticality study of the energy objects heat pipes","authors":"","doi":"10.36652/0869-4931-2020-74-3-99-101","DOIUrl":null,"url":null,"abstract":"The estimation of the results informativeness of the laser scanning at the verticality study of the energy objects heat pipes is considered. It is shown that when conducting studies of the many heat pipes slopes with different heights, a directly proportional relationship between the height of the pipe and the number of measurements should be provided. In this case, the choice of the optimal communication type between these specified factors does not depend on the standard deviation of the conducted measurements results using laser scanners.","PeriodicalId":309803,"journal":{"name":"Automation. Modern Techologies","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Automation. Modern Techologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.36652/0869-4931-2020-74-3-99-101","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The estimation of the results informativeness of the laser scanning at the verticality study of the energy objects heat pipes is considered. It is shown that when conducting studies of the many heat pipes slopes with different heights, a directly proportional relationship between the height of the pipe and the number of measurements should be provided. In this case, the choice of the optimal communication type between these specified factors does not depend on the standard deviation of the conducted measurements results using laser scanners.
能量物体热管垂直性研究中激光扫描结果的信息量评价
考虑了能量物体热管垂直性研究中激光扫描结果信息量的估计问题。结果表明,在对许多具有不同高度的热管斜坡进行研究时,应提供管道高度与测量次数之间的正比关系。在这种情况下,这些指定因素之间的最佳通信类型的选择并不取决于使用激光扫描仪进行测量结果的标准偏差。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信