{"title":"Potential of CF3I gas mixture as an insulation medium in gas-insulated equipment","authors":"L. Chen, P. Widger, M. S. Kamarudin, H. Griffiths, A. Haddad","doi":"10.1109/CEIDP.2015.7352013","DOIUrl":null,"url":null,"abstract":"SF6 is a widely used gas medium in gas-insulated equipment. Due to the high global warming potential and long atmospheric lifetime of SF6, there has been research into a new environmentally friendly replacement gas. This paper describes the research carried out at Cardiff University on CF3I gas and its mixture as a substitute insulation medium for SF6 in gas-insulated lines (GIL). A reduced-scale coaxial test system having the electric field properties of a full-scale 400 kV GIL system was fabricated. The design of the reduced-scale coaxial test system was simulated to ensure that the highest electric field would be along the center of the conductor. The coaxial prototype was then tested under a standard lightning impulse (1.2/50) in order to determine the 50% breakdown voltage for such a system when insulated with CF3I gas mixture. It was found that CF3I has the potential to replace SF6 as an insulation medium in GIL. A full-scale short length GIL demonstrator is being assembled in the laboratory to evaluate further the feasibility of using a CF3I gas mixture as an insulation medium.","PeriodicalId":432404,"journal":{"name":"2015 IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP)","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-12-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.2015.7352013","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9
Abstract
SF6 is a widely used gas medium in gas-insulated equipment. Due to the high global warming potential and long atmospheric lifetime of SF6, there has been research into a new environmentally friendly replacement gas. This paper describes the research carried out at Cardiff University on CF3I gas and its mixture as a substitute insulation medium for SF6 in gas-insulated lines (GIL). A reduced-scale coaxial test system having the electric field properties of a full-scale 400 kV GIL system was fabricated. The design of the reduced-scale coaxial test system was simulated to ensure that the highest electric field would be along the center of the conductor. The coaxial prototype was then tested under a standard lightning impulse (1.2/50) in order to determine the 50% breakdown voltage for such a system when insulated with CF3I gas mixture. It was found that CF3I has the potential to replace SF6 as an insulation medium in GIL. A full-scale short length GIL demonstrator is being assembled in the laboratory to evaluate further the feasibility of using a CF3I gas mixture as an insulation medium.