Bias Offset Correction Technique For Uncooled Infrared Bolometer Sensor Readout IC

Sang Won Park, S. Hwang, Jang-Woo Ryu, S. Hong, M. Sung
{"title":"Bias Offset Correction Technique For Uncooled Infrared Bolometer Sensor Readout IC","authors":"Sang Won Park, S. Hwang, Jang-Woo Ryu, S. Hong, M. Sung","doi":"10.1109/EDSSC.2005.1635378","DOIUrl":null,"url":null,"abstract":"Infrared bolometer sensor's variation is detected by voltage drop between a reference resistor and a bolometer resistor in this architecture. One of the serious problems in this architecture is that these resistors value has a process variation. So common-mode level could be different from expectation value in room temperature. Different common-mode level could lead to wrong output at the end of readout circuit. We suggest useful method to solve this problem. Difference correction using capacitor has reduced CM level difference to 88.5 % for I MΩ bolometer and reference resistor's 10 % variation.","PeriodicalId":429314,"journal":{"name":"2005 IEEE Conference on Electron Devices and Solid-State Circuits","volume":"188 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2005-12-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2005 IEEE Conference on Electron Devices and Solid-State Circuits","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EDSSC.2005.1635378","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

Infrared bolometer sensor's variation is detected by voltage drop between a reference resistor and a bolometer resistor in this architecture. One of the serious problems in this architecture is that these resistors value has a process variation. So common-mode level could be different from expectation value in room temperature. Different common-mode level could lead to wrong output at the end of readout circuit. We suggest useful method to solve this problem. Difference correction using capacitor has reduced CM level difference to 88.5 % for I MΩ bolometer and reference resistor's 10 % variation.
非制冷红外测热计传感器读出IC的偏置偏置校正技术
红外热计传感器的变化是通过参考电阻和热计电阻之间的电压降来检测的。这种结构的一个严重问题是,这些电阻器的值具有工艺变化。所以共模能级可以不同于室温下的期望值。不同的共模电平会导致读出电路末端输出错误。我们提出了解决这个问题的有效方法。对于I MΩ测热计和参考电阻的10%变化,使用电容的差值校正将CM电平差降低到88.5%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信