Is It Necessary to Add Aprotinin Before Measuring The Level of Irisin in Serum and Plasma Samples ?

E. Şahi̇n, Ecem Handiri, Diler Us Altay, E. E. Keha
{"title":"Is It Necessary to Add Aprotinin Before Measuring The Level of Irisin in Serum and Plasma Samples ?","authors":"E. Şahi̇n, Ecem Handiri, Diler Us Altay, E. E. Keha","doi":"10.59518/farabimedj.1245113","DOIUrl":null,"url":null,"abstract":"Irisin is a myokine with 112 aminoacids and its level is regulated by peroxisome proliferator-activated receptor-γ coactivator1-α (PGC1-α). It is released into blood circulation from skeletal muscle tissue after a proteolytic cleavage of extracellular domain of Fibronectin type III domain-containing protein 5 (FNDC5), a type I integral membrain protein. Aprotinin is a polivalent serin protease inhibitor. It is added to sample solutions such as serum, plasma or tissue extracts in order to inhibit serine proteases found in the sample medium. So, degradation of the proteins to be measured can be prevented. These study has been made to get a preliminary information in order to see if any irisin loss could be seen in these samples which are frequently needed to be kept at -80°C for a long time. For this purpose, blood samples have been taken from 10 men and 10 women volunteers with ages between 25-40 and aprotinin has been added to the plasma and the serum samples and have been kept at -80°C for 3 months. At the end of 3 months, irisin levels of these samples with aprotinin and without aprotinin have been determined by ELISA. Statistical analysis of the results has shown an insignificant differance between the plasma samples with or without aprotinin (p=0.525) and a significant decrease between the serum samples with and without aprotinin (p=0.009). In conclusion, with the results of this study, no net decision could have been achieved to add aprotinin to the samples for irisin determination with ELISA in plasma and serum kept at -80°C for about 3 months.","PeriodicalId":399200,"journal":{"name":"Farabi Tıp Dergisi","volume":"83 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-03-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Farabi Tıp Dergisi","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.59518/farabimedj.1245113","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Irisin is a myokine with 112 aminoacids and its level is regulated by peroxisome proliferator-activated receptor-γ coactivator1-α (PGC1-α). It is released into blood circulation from skeletal muscle tissue after a proteolytic cleavage of extracellular domain of Fibronectin type III domain-containing protein 5 (FNDC5), a type I integral membrain protein. Aprotinin is a polivalent serin protease inhibitor. It is added to sample solutions such as serum, plasma or tissue extracts in order to inhibit serine proteases found in the sample medium. So, degradation of the proteins to be measured can be prevented. These study has been made to get a preliminary information in order to see if any irisin loss could be seen in these samples which are frequently needed to be kept at -80°C for a long time. For this purpose, blood samples have been taken from 10 men and 10 women volunteers with ages between 25-40 and aprotinin has been added to the plasma and the serum samples and have been kept at -80°C for 3 months. At the end of 3 months, irisin levels of these samples with aprotinin and without aprotinin have been determined by ELISA. Statistical analysis of the results has shown an insignificant differance between the plasma samples with or without aprotinin (p=0.525) and a significant decrease between the serum samples with and without aprotinin (p=0.009). In conclusion, with the results of this study, no net decision could have been achieved to add aprotinin to the samples for irisin determination with ELISA in plasma and serum kept at -80°C for about 3 months.
在测定血清和血浆样本中鸢尾素水平前是否需要添加抑酶蛋白?
鸢尾素是一种含有112个氨基酸的肌肉因子,其水平受过氧化物酶体增殖物激活受体-γ辅助激活因子1-α (PGC1-α)的调控。FNDC5是一种I型整体膜蛋白,它是在纤维连接蛋白III型结构域含蛋白5 (FNDC5)的胞外结构域发生蛋白水解裂解后,从骨骼肌组织释放到血液循环中。抑酶蛋白是一种多价丝氨酸蛋白酶抑制剂。它被添加到样品溶液中,如血清、血浆或组织提取物,以抑制样品培养基中发现的丝氨酸蛋白酶。因此,可以防止待测蛋白质的降解。这些样品经常需要在-80°C下长时间保存,为了了解这些样品中是否有鸢尾素的损失,进行了初步的研究。为此,从年龄在25-40岁之间的10名男性和10名女性志愿者中采集了血液样本,并在血浆和血清样本中添加了抑酶蛋白,并在-80°C下保存了3个月。3个月后,用酶联免疫吸附试验(ELISA)测定含抑酶蛋白和不含抑酶蛋白样品的鸢尾素水平。统计分析结果显示,血清中含抑蛋白蛋白与不含抑蛋白蛋白之间差异不显著(p=0.525),血清中含抑蛋白蛋白与不含抑蛋白蛋白之间差异显著(p=0.009)。综上所述,根据本研究结果,在-80°C保存约3个月的血浆和血清中,尚不能确定是否在ELISA检测鸢尾素的样品中添加抑酶蛋白。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信