A New Learning Experience in Gas Turbine Generator a Case Study of Blackout Conditions Due to Tripping of Gtg and the Necessary Corrective Actions to Prevent the Reoccurrence

{"title":"A New Learning Experience in Gas Turbine Generator a Case Study of Blackout Conditions Due to Tripping of Gtg and the Necessary Corrective Actions to Prevent the Reoccurrence","authors":"","doi":"10.33140/pcii.03.01.09","DOIUrl":null,"url":null,"abstract":"This paper describes about the case study of a very interesting and peculiar blackout conditions (total power failure) arising out of both the Gas Turbine Generators (Two units of GTG, namely GTG-01 & GTG-02) units back to back tripping in a short span of a week’s time. It brings out the various observations noted during that condition and it’s root cause analysis. It also highlights the various possible corrective actions in a short term and long term basis to prevent the reoccurrence of such blackout situations.","PeriodicalId":355186,"journal":{"name":"Petroleum and Chemical Industry International","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-09-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Petroleum and Chemical Industry International","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33140/pcii.03.01.09","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This paper describes about the case study of a very interesting and peculiar blackout conditions (total power failure) arising out of both the Gas Turbine Generators (Two units of GTG, namely GTG-01 & GTG-02) units back to back tripping in a short span of a week’s time. It brings out the various observations noted during that condition and it’s root cause analysis. It also highlights the various possible corrective actions in a short term and long term basis to prevent the reoccurrence of such blackout situations.
燃气轮机发电机组的新经验——以Gtg跳闸停电事故为例及预防再次发生的必要纠正措施
本文描述了一个非常有趣和特殊的停电情况(全停电)的案例研究,由两个燃气轮机机组(GTG的两个机组,即GTG-01和GTG-02)在短短一周的时间内背对跳闸引起的。它提出了在这种情况下的各种观察结果,并对根本原因进行了分析。它还强调了短期和长期基础上的各种可能的纠正措施,以防止此类停电情况的再次发生。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信