Telecommunications Power Supply System in the New International Telecommunication Building in Japan

H. Yamaguchi, H. Yoshida
{"title":"Telecommunications Power Supply System in the New International Telecommunication Building in Japan","authors":"H. Yamaguchi, H. Yoshida","doi":"10.1109/INTLEC.1979.4793668","DOIUrl":null,"url":null,"abstract":"To meet the increasing demands of international telecommunications in Japan, 32-storied building (KDD Building) was constructed in Tokyo in 1974. In order to feed power to the telecommunication equipments, the constant voltage and constant frequency uninterruptible power plant of 4000 kVA which will meet the demand of power consumption required for the future increase of telecommunication equipments was decided to be installed in the basement. AC power generated in this power plant is fed to the telecommunication equipment floors by distribution trunk lines where the AC power is converted into AC or DC power required for each telecommunication equipment. This paper describes the design, configuration and reliability of the telecommunications power supply system (UPS).","PeriodicalId":177302,"journal":{"name":"INTELEC - 1979 International Telecommunications Energy Conference","volume":"111 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1979-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"INTELEC - 1979 International Telecommunications Energy Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/INTLEC.1979.4793668","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

To meet the increasing demands of international telecommunications in Japan, 32-storied building (KDD Building) was constructed in Tokyo in 1974. In order to feed power to the telecommunication equipments, the constant voltage and constant frequency uninterruptible power plant of 4000 kVA which will meet the demand of power consumption required for the future increase of telecommunication equipments was decided to be installed in the basement. AC power generated in this power plant is fed to the telecommunication equipment floors by distribution trunk lines where the AC power is converted into AC or DC power required for each telecommunication equipment. This paper describes the design, configuration and reliability of the telecommunications power supply system (UPS).
日本新国际电信大厦的通信供电系统
为了满足日本日益增长的国际电信需求,1974年在东京建造了32层楼(KDD大厦)。为了给通信设备供电,决定在地下室安装4000千伏安的恒压恒频不间断电站,以满足未来通信设备增加的用电量需求。该发电厂产生的交流电力通过配电干线输送到各通信设备层,在配电干线上将交流电源转换成各通信设备所需的交流或直流电源。本文介绍了电信供电系统(UPS)的设计、配置和可靠性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信