Maximum interrupting Capacity of CuCr Contacts under the effect of uniform axial magnetic field (AMF)

A. Chaly, I. N. Poluyanova, V. Poluyanov
{"title":"Maximum interrupting Capacity of CuCr Contacts under the effect of uniform axial magnetic field (AMF)","authors":"A. Chaly, I. N. Poluyanova, V. Poluyanov","doi":"10.1109/DEIV.2006.357301","DOIUrl":null,"url":null,"abstract":"Maximum interrupting capacity of the butt CuCr 70/30 contacts at external uniform AMF has been experimentally investigated for AMF induction range 0-1.2 T. It has been found that dependency of maximum interrupting current density versus AMF induction has a tendency to saturate when the latter achieves the level of the first characteristic point B1 on Volt-Tesla characteristic. Radial energy losses have been evaluated on the basis of measured anode mass losses. 1D thermal model has been used for evaluation maximum interrupting current density. At the same time radial energy losses have been taken into consideration. Calculated results demonstrate good agreement with the experimental data if critical temperature equal to ~2000 K is considered. This value of critical temperature is supported by several experiments described in literature","PeriodicalId":369861,"journal":{"name":"2006 International Symposium on Discharges and Electrical Insulation in Vacuum","volume":"50 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 International Symposium on Discharges and Electrical Insulation in Vacuum","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/DEIV.2006.357301","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Maximum interrupting capacity of the butt CuCr 70/30 contacts at external uniform AMF has been experimentally investigated for AMF induction range 0-1.2 T. It has been found that dependency of maximum interrupting current density versus AMF induction has a tendency to saturate when the latter achieves the level of the first characteristic point B1 on Volt-Tesla characteristic. Radial energy losses have been evaluated on the basis of measured anode mass losses. 1D thermal model has been used for evaluation maximum interrupting current density. At the same time radial energy losses have been taken into consideration. Calculated results demonstrate good agreement with the experimental data if critical temperature equal to ~2000 K is considered. This value of critical temperature is supported by several experiments described in literature
均匀轴向磁场作用下CuCr触点的最大中断容量
在0-1.2 t的电流感应范围内,对口CuCr 70/30触点在外部均匀电流感应下的最大中断能力进行了实验研究。结果发现,当电流感应达到伏特斯拉特性的第一个特征点B1时,最大中断电流密度与电流感应的关系趋于饱和。根据测量的阳极质量损失计算了径向能量损失。采用一维热模型对最大断流密度进行了评价。同时考虑了径向能量损失。当临界温度为~2000 K时,计算结果与实验数据吻合较好。这一临界温度值得到了文献中几个实验的支持
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信