{"title":"Study on the influence of TCSC structure and control on SSR damping using an improved s-domain model","authors":"Fernando Cattan Jusan, S. Gomes, G. Taranto","doi":"10.1109/TDC-LA.2010.5762854","DOIUrl":null,"url":null,"abstract":"This paper investigates the influence of basic TCSC main circuit structure and control on subsynchronous torsional damping of a nearby turbine-generator. An improved s-domain model based on dynamic phasor approach was used to obtain the results presented in the paper. The study is conducted on the System-1 of the IEEE Second Benchmark Model. Detailed eigenvalue analyses are carried out in order to evaluate the effect of the proportion of TCSC to FSC, Boost Factor and size of TCSC reactor on subsynchronous damping. The influence of constant current controller and synchronization system (PLL) parameters is also investigated. Finally, a simple Subsynchronous Damping Controller (SSDC) is added to the TCSC main control in order to demonstrate that the SSR damping capability of TCSC may be enhanced by proper modulation of firing angle. The results obtained in the time domain simulations are validated through PSCAD/EMTDC simulations.","PeriodicalId":222318,"journal":{"name":"2010 IEEE/PES Transmission and Distribution Conference and Exposition: Latin America (T&D-LA)","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 IEEE/PES Transmission and Distribution Conference and Exposition: Latin America (T&D-LA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TDC-LA.2010.5762854","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

This paper investigates the influence of basic TCSC main circuit structure and control on subsynchronous torsional damping of a nearby turbine-generator. An improved s-domain model based on dynamic phasor approach was used to obtain the results presented in the paper. The study is conducted on the System-1 of the IEEE Second Benchmark Model. Detailed eigenvalue analyses are carried out in order to evaluate the effect of the proportion of TCSC to FSC, Boost Factor and size of TCSC reactor on subsynchronous damping. The influence of constant current controller and synchronization system (PLL) parameters is also investigated. Finally, a simple Subsynchronous Damping Controller (SSDC) is added to the TCSC main control in order to demonstrate that the SSR damping capability of TCSC may be enhanced by proper modulation of firing angle. The results obtained in the time domain simulations are validated through PSCAD/EMTDC simulations.
利用改进的s域模型研究TCSC结构和控制对SSR阻尼的影响
本文研究了TCSC基本主电路结构和控制对附近汽轮发电机亚同步扭转阻尼的影响。基于动态相量法的改进s域模型得到了本文的结果。本研究是在IEEE第二基准模型的System-1上进行的。为了评估TCSC与FSC的比例、升压因子和TCSC电抗器尺寸对次同步阻尼的影响,进行了详细的特征值分析。研究了恒流控制器和同步系统(PLL)参数的影响。最后,在TCSC主控制器中加入一个简单的次同步阻尼控制器(SSDC),以证明通过适当调制发射角可以增强TCSC的次同步阻尼能力。通过PSCAD/EMTDC仿真验证了时域仿真结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信