{"title":"Respiration rhythm monitoring in sleep based on weight movement using hetero-core fiber optic sensors","authors":"M. Nishiyama, M. Miyamoto, K. Watanabe","doi":"10.1109/ICCAS.2010.5669885","DOIUrl":null,"url":null,"abstract":"This paper describes respiration monitoring during sleep using hetero-core fiber optic pressure sensors. The hetero-core fiber optic sensor has high sensitivity to macro-bending action as a result of the core diameter difference corresponding to the sensor portion due to stable single-mode transmission. Pressure sensors employing hetero-core fiber optics were fabricated to have a wide sensitivity to small pressure changes resulting from minute body motions such as respiration in sleep and large pressure changes such as a roll-over action. The fabricated pressure sensors were installed in a conventional bed. The pressure characteristic performance of all the fabricated pressure sensors was found to show a monotonic response in the optical loss change with weight changes. The sensitivities of the hetero-core pressure sensors for a weight change of 3.0 kg were in the range of 0.55-1.80 dB. Additionally, even in the case of different body postures such as lying on one's side, a slight body movement due to respiration could be detected by the hetero-core pressure sensors.","PeriodicalId":158687,"journal":{"name":"ICCAS 2010","volume":"176 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-12-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ICCAS 2010","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICCAS.2010.5669885","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7
Abstract
This paper describes respiration monitoring during sleep using hetero-core fiber optic pressure sensors. The hetero-core fiber optic sensor has high sensitivity to macro-bending action as a result of the core diameter difference corresponding to the sensor portion due to stable single-mode transmission. Pressure sensors employing hetero-core fiber optics were fabricated to have a wide sensitivity to small pressure changes resulting from minute body motions such as respiration in sleep and large pressure changes such as a roll-over action. The fabricated pressure sensors were installed in a conventional bed. The pressure characteristic performance of all the fabricated pressure sensors was found to show a monotonic response in the optical loss change with weight changes. The sensitivities of the hetero-core pressure sensors for a weight change of 3.0 kg were in the range of 0.55-1.80 dB. Additionally, even in the case of different body postures such as lying on one's side, a slight body movement due to respiration could be detected by the hetero-core pressure sensors.