Seismic collapse safety of reinforced concrete moment resisting frames with/without beam-column joint detailing

N. Ahmad, M. Rizwan, M. Ashraf, A. Khan, Qaisar Ali
{"title":"Seismic collapse safety of reinforced concrete moment resisting frames with/without beam-column joint detailing","authors":"N. Ahmad, M. Rizwan, M. Ashraf, A. Khan, Qaisar Ali","doi":"10.5459/BNZSEE.54.1.1-20","DOIUrl":null,"url":null,"abstract":"FEMA-P695 procedure was applied for seismic collapse safety evaluation of reinforced concrete moment resisting frames with/without beam-column joint detailing common in Pakistan. The deficient frame lacks shear reinforcement in joints and uses concrete of low compressive strength. Shake-table tests were performed on 1:3 reduced scale two-story models, to understand the progressive inelastic response of chosen frames and calibrate the inelastic finite-element based models. The seismic design factors i.e. response modification coefficient, overstrength, ductility, and displacement amplification factors (R, W0, Rμ, Cd) were quantified. Response modification factor R = 7.05 was obtained for the frame with beam-column joint detailing while R = 5.30 was obtained for the deficient frame. The corresponding deflection amplification factor Cd/R was found equal to 0.82 and 1.03, respectively. A suite of design spectrum compatible accelerograms was obtained from PEER strong ground motions for incremental dynamic analysis of numerical models. Collapse fragility functions were developed using a probabilistic nonlinear dynamic reliability-based method. The collapse margin ratio (CMR) was calculated as the ratio of seismic intensity corresponding to the 50th percentile collapse probability to the seismic intensity corresponding to the MCE level ground motions. It was critically compared with the acceptable CMR (i.e. the CMR computed with reference to a seismic intensity corresponding to the 10% collapse probability instead of MCE level ground motions). Frame with shear reinforcement in beam-column joints has achieved CMR 11% higher than the acceptable thus passing the criterion. However, the deficient frame achieved CMR 29% less than the conforming frame. This confirms the efficacy of beam-column joint detailing in reducing collapse risk.","PeriodicalId":343472,"journal":{"name":"Bulletin of the New Zealand National Society for Earthquake Engineering","volume":"129 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bulletin of the New Zealand National Society for Earthquake Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5459/BNZSEE.54.1.1-20","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

FEMA-P695 procedure was applied for seismic collapse safety evaluation of reinforced concrete moment resisting frames with/without beam-column joint detailing common in Pakistan. The deficient frame lacks shear reinforcement in joints and uses concrete of low compressive strength. Shake-table tests were performed on 1:3 reduced scale two-story models, to understand the progressive inelastic response of chosen frames and calibrate the inelastic finite-element based models. The seismic design factors i.e. response modification coefficient, overstrength, ductility, and displacement amplification factors (R, W0, Rμ, Cd) were quantified. Response modification factor R = 7.05 was obtained for the frame with beam-column joint detailing while R = 5.30 was obtained for the deficient frame. The corresponding deflection amplification factor Cd/R was found equal to 0.82 and 1.03, respectively. A suite of design spectrum compatible accelerograms was obtained from PEER strong ground motions for incremental dynamic analysis of numerical models. Collapse fragility functions were developed using a probabilistic nonlinear dynamic reliability-based method. The collapse margin ratio (CMR) was calculated as the ratio of seismic intensity corresponding to the 50th percentile collapse probability to the seismic intensity corresponding to the MCE level ground motions. It was critically compared with the acceptable CMR (i.e. the CMR computed with reference to a seismic intensity corresponding to the 10% collapse probability instead of MCE level ground motions). Frame with shear reinforcement in beam-column joints has achieved CMR 11% higher than the acceptable thus passing the criterion. However, the deficient frame achieved CMR 29% less than the conforming frame. This confirms the efficacy of beam-column joint detailing in reducing collapse risk.
带/不带梁柱节点的钢筋混凝土抗弯矩框架的地震倒塌安全性
采用FEMA-P695程序对巴基斯坦常见的带/不带梁柱节点的钢筋混凝土抗弯矩框架进行了地震倒塌安全性评价。缺陷框架在接缝处缺少抗剪钢筋,使用抗压强度低的混凝土。为了了解所选框架的逐级非弹性响应,并对基于非弹性有限元的模型进行校正,对1:3缩小比例的两层模型进行了振动台试验。对反应修正系数、超强系数、延性系数和位移放大系数(R、W0、Rμ、Cd)等抗震设计因子进行了量化。有梁柱节点节点的框架响应修正系数R = 7.05,无梁柱节点的框架响应修正系数R = 5.30。相应的挠曲放大系数Cd/R分别为0.82和1.03。从PEER强地震动中获得了一套设计谱兼容加速度图,用于数值模型的增量动力分析。采用基于概率非线性动态可靠度的方法,建立了结构的崩溃易损性函数。崩塌边缘比(CMR)计算为第50百分位崩塌概率对应的地震烈度与MCE水平地震动对应的地震烈度之比。将其与可接受的CMR(即参考对应于10%倒塌概率而不是MCE水平地面运动的地震烈度计算的CMR)进行了严格比较。梁-柱节点剪力加固框架的CMR比可接受值高11%,通过了规范。然而,缺陷框架的CMR比符合框架低29%。这证实了梁柱节点详设在降低倒塌风险方面的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信