{"title":"3D Microelectrodes for Coulometric Screening in Microfabricated Lab-on-a-Chip Devices","authors":"T. Roussel, R. Pai, M. Grain, D. Jackson, L. Sztaberek, K. Walsh, J. Naber, R. Baldwin, R. Keynton","doi":"10.1109/MMB.2006.251537","DOIUrl":null,"url":null,"abstract":"This paper presents results indicating the complete oxidation of an analyte using a three-dimensional, large surface area microelectrode in a lab-on-a-chip (LOC) device. Traditional photolithographic fabrication techniques were used to construct the microchip prototype, with the exception of the 3D electrodes. Experiments were performed using a flow-injection scheme, where a 1 mM sample of catechol was directed towards the detection reservoir. Oxidation voltage at a planar upstream electrode was increased from 0 to 1.2 V in 0.1 volt increments and was shown to reduce the detection level of the sample at a downstream planar electrode (1.2 V). Oxidation voltage at the upstream 3D electrode was changed in a similar manner and was shown to completely eliminate detection at a downstream planar electrode. These results indicate the complete removal of sample from the flow stream, suggesting that 3D micro fabricated electrodes could be used in an LOC device for coulometric screening","PeriodicalId":170356,"journal":{"name":"2006 International Conference on Microtechnologies in Medicine and Biology","volume":"28 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-05-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 International Conference on Microtechnologies in Medicine and Biology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MMB.2006.251537","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

This paper presents results indicating the complete oxidation of an analyte using a three-dimensional, large surface area microelectrode in a lab-on-a-chip (LOC) device. Traditional photolithographic fabrication techniques were used to construct the microchip prototype, with the exception of the 3D electrodes. Experiments were performed using a flow-injection scheme, where a 1 mM sample of catechol was directed towards the detection reservoir. Oxidation voltage at a planar upstream electrode was increased from 0 to 1.2 V in 0.1 volt increments and was shown to reduce the detection level of the sample at a downstream planar electrode (1.2 V). Oxidation voltage at the upstream 3D electrode was changed in a similar manner and was shown to completely eliminate detection at a downstream planar electrode. These results indicate the complete removal of sample from the flow stream, suggesting that 3D micro fabricated electrodes could be used in an LOC device for coulometric screening
微制造芯片实验室设备库仑筛选的三维微电极
本文提出的结果表明,分析物完全氧化使用三维,大表面积微电极在实验室芯片上(LOC)装置。除了3D电极外,微芯片原型采用了传统的光刻制造技术。实验采用流动注射方案,其中1毫米的儿茶酚样品被定向到检测储层。平面上游电极上的氧化电压以0.1伏的增量从0增加到1.2 V,并显示出降低了下游平面电极(1.2 V)上样品的检测水平。上游3D电极上的氧化电压以类似的方式变化,并显示出完全消除了下游平面电极上的检测。这些结果表明样品完全从流动中去除,表明3D微制造电极可以用于LOC装置进行库仑筛选
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信