Using the FDS Technique in Transformer Factory Drying

D. García, D. Cordoba, J. Vasquez
{"title":"Using the FDS Technique in Transformer Factory Drying","authors":"D. García, D. Cordoba, J. Vasquez","doi":"10.23919/ARWtr.2019.8930177","DOIUrl":null,"url":null,"abstract":"This paper presents an approach for the feasible use of frequency-domain spectroscopy technique, to evaluate transformer factory drying and by this, to determine the most suitable moment to finish the drying process. To enable the use of FDS in transformer factory drying, the reference dielectric response curves of the air-paper insulation system of the transformers under drying, are necessary. Those reference curves were obtained in two ways: First scale models were used to emulate the insulation system between windings, the second way consisted in the simulation of the inter windings insulate through a finite element model. The feasibility of frequency-domain spectroscopy technique in transformer factory drying, as well as the methods to obtain the dielectric response reference curves, were validated through several experiments, and by the drying of five transformers, all carried out in the facilities of Transformadores de Colombia.","PeriodicalId":117389,"journal":{"name":"2019 6th International Advanced Research Workshop on Transformers (ARWtr)","volume":"44 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 6th International Advanced Research Workshop on Transformers (ARWtr)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/ARWtr.2019.8930177","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This paper presents an approach for the feasible use of frequency-domain spectroscopy technique, to evaluate transformer factory drying and by this, to determine the most suitable moment to finish the drying process. To enable the use of FDS in transformer factory drying, the reference dielectric response curves of the air-paper insulation system of the transformers under drying, are necessary. Those reference curves were obtained in two ways: First scale models were used to emulate the insulation system between windings, the second way consisted in the simulation of the inter windings insulate through a finite element model. The feasibility of frequency-domain spectroscopy technique in transformer factory drying, as well as the methods to obtain the dielectric response reference curves, were validated through several experiments, and by the drying of five transformers, all carried out in the facilities of Transformadores de Colombia.
FDS技术在变压器厂干燥中的应用
本文提出了一种可行的利用频域光谱技术来评价变压器工厂干燥的方法,并以此来确定完成干燥过程的最合适时机。为了使FDS在变压器工厂干燥中使用,需要有干燥时变压器空气-纸绝缘系统的参考介电响应曲线。通过两种方法获得参考曲线:一是采用比例模型模拟绕组间绝缘系统,二是采用有限元模型模拟绕组间绝缘系统。频域光谱技术在变压器工厂干燥中的可行性,以及获得介质响应参考曲线的方法,通过多次实验验证,并通过在Transformadores de Colombia工厂进行的5台变压器的干燥进行验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信