Dynamic Studies for 100% Converter-based Irish Power System

X. Zhao, D. Flynn
{"title":"Dynamic Studies for 100% Converter-based Irish Power System","authors":"X. Zhao, D. Flynn","doi":"10.1049/icp.2021.1351","DOIUrl":null,"url":null,"abstract":"Given increasing shares of wind and/or solar power in many power systems, the possibility of a 100% power converter-based system becomes more plausible. Consequently, the dynamic response of the Irish transmission system with 100% (grid-following and grid-forming) power converters under 3-phase faults is investigated. Time domain simulations show that when active or reactive current prioritisation limits are applied, grid-forming converters can introduce large high-frequency oscillations, but a scaling-down current limitation approach can help to avoid such problems. Furthermore, applying scaling-down current limits, together with freezing the virtual angular speed, for a grid-forming converter, can limit the current and enhance transient stability during faults. Finally, with modified controls applied to the grid-following converters, the grid-forming requirement can be reduced from approximately 40% to less than 30%, with the future Irish grid remaining robust against bolted 3-phase faults, and oscillations quickly damped out during and post fault.","PeriodicalId":223615,"journal":{"name":"The 9th Renewable Power Generation Conference (RPG Dublin Online 2021)","volume":"47 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The 9th Renewable Power Generation Conference (RPG Dublin Online 2021)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1049/icp.2021.1351","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Given increasing shares of wind and/or solar power in many power systems, the possibility of a 100% power converter-based system becomes more plausible. Consequently, the dynamic response of the Irish transmission system with 100% (grid-following and grid-forming) power converters under 3-phase faults is investigated. Time domain simulations show that when active or reactive current prioritisation limits are applied, grid-forming converters can introduce large high-frequency oscillations, but a scaling-down current limitation approach can help to avoid such problems. Furthermore, applying scaling-down current limits, together with freezing the virtual angular speed, for a grid-forming converter, can limit the current and enhance transient stability during faults. Finally, with modified controls applied to the grid-following converters, the grid-forming requirement can be reduced from approximately 40% to less than 30%, with the future Irish grid remaining robust against bolted 3-phase faults, and oscillations quickly damped out during and post fault.
基于100%变流器的爱尔兰电力系统动态研究
鉴于风能和/或太阳能在许多电力系统中所占的份额越来越大,100%基于电源转换器的系统的可能性变得更加可信。因此,研究了100%(随网和成网)变流器在三相故障下爱尔兰输电系统的动态响应。时域模拟表明,当应用有功或无功电流优先级限制时,电网形成转换器可能会引入大的高频振荡,但缩小电流限制方法可以帮助避免此类问题。此外,对成网变流器采用缩比电流限制和冻结虚拟角速度,可以限制电流,提高故障时的暂态稳定性。最后,通过对电网跟随转换器的改进控制,电网形成要求可以从大约40%降低到30%以下,未来的爱尔兰电网在螺栓连接的三相故障中保持稳健,并且在故障期间和故障后的振荡迅速得到抑制。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信