{"title":"Optimal location and setting of TCSC under single line contingency using Mixed Integer Nonlinear Programming","authors":"R. Etemad, R. Navabi, H. Shayanfar","doi":"10.1109/EEEIC.2010.5489985","DOIUrl":null,"url":null,"abstract":"This paper present a novel approach to determine optimal location, number and parameter setting of Thyristor Controlled Series Capacitor (TCSC) under single line contingency (N-1 contingency). Mixed Integer Nonlinear Programming (MINLP) based on Line Flow Based (LFB) equations is being used for this purpose as a fast and robust approach. Contingency analysis is performed to detect and rank the severest one-line fault contingency in a power system. The optimization objective function is consists of line overloads alleviation and bus voltage magnitudes enhancement. To validate the effectiveness of proposed approach, simulations are carried out on IEEE 9 bus system. The obtained results show that TCSC is very effective device in security enhancement under single line contingency, considering its smooth and rapid reactance change according to system requirements.","PeriodicalId":197298,"journal":{"name":"2010 9th International Conference on Environment and Electrical Engineering","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 9th International Conference on Environment and Electrical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EEEIC.2010.5489985","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13
Abstract
This paper present a novel approach to determine optimal location, number and parameter setting of Thyristor Controlled Series Capacitor (TCSC) under single line contingency (N-1 contingency). Mixed Integer Nonlinear Programming (MINLP) based on Line Flow Based (LFB) equations is being used for this purpose as a fast and robust approach. Contingency analysis is performed to detect and rank the severest one-line fault contingency in a power system. The optimization objective function is consists of line overloads alleviation and bus voltage magnitudes enhancement. To validate the effectiveness of proposed approach, simulations are carried out on IEEE 9 bus system. The obtained results show that TCSC is very effective device in security enhancement under single line contingency, considering its smooth and rapid reactance change according to system requirements.