Design and Implementation of a Voltage Harmonic Elimination Control Method for the Single-Phase Inverter

B. Proca, M. Comanescu
{"title":"Design and Implementation of a Voltage Harmonic Elimination Control Method for the Single-Phase Inverter","authors":"B. Proca, M. Comanescu","doi":"10.1109/PEDG48541.2020.9244362","DOIUrl":null,"url":null,"abstract":"Single-phase voltage-source converters are widely used in power conversion systems like grid-interfaced photovoltaic arrays. This paper presents a control method for the single-phase inverter that is looking to reduce the harmonic content of the output voltage, especially for the situation when the inverter feeds a crest-factor load. In this case, the currents are non-sinusoidal and relatively distorted; as a result, the THD is higher than the specification allows. The method proposed uses a voltage controller followed by a current controller - both are implemented in the stationary reference frame. The voltage controller uses a harmonic elimination method based on modulation-demodulation. This approach regulates the fundamental of the voltage and is also used to attempt the elimination of some higher order harmonics. In the simulations and experiments shown in the paper, the regulation and harmonic elimination scheme is implemented for the fundamental and for the 3rd, 5th and 7th harmonics of the voltage. The scheme can be expanded further to eliminate the harmonics of even higher order. It is shown that the control method proposed significantly reduces the Total Harmonic Distortion (THD) of the output voltage, from 5.8% (at full load, uncompensated) to 1.6% (at full load, with compensation). The control method proposed is validated with simulations and experimental tests.","PeriodicalId":249484,"journal":{"name":"2020 IEEE 11th International Symposium on Power Electronics for Distributed Generation Systems (PEDG)","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-09-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE 11th International Symposium on Power Electronics for Distributed Generation Systems (PEDG)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEDG48541.2020.9244362","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Single-phase voltage-source converters are widely used in power conversion systems like grid-interfaced photovoltaic arrays. This paper presents a control method for the single-phase inverter that is looking to reduce the harmonic content of the output voltage, especially for the situation when the inverter feeds a crest-factor load. In this case, the currents are non-sinusoidal and relatively distorted; as a result, the THD is higher than the specification allows. The method proposed uses a voltage controller followed by a current controller - both are implemented in the stationary reference frame. The voltage controller uses a harmonic elimination method based on modulation-demodulation. This approach regulates the fundamental of the voltage and is also used to attempt the elimination of some higher order harmonics. In the simulations and experiments shown in the paper, the regulation and harmonic elimination scheme is implemented for the fundamental and for the 3rd, 5th and 7th harmonics of the voltage. The scheme can be expanded further to eliminate the harmonics of even higher order. It is shown that the control method proposed significantly reduces the Total Harmonic Distortion (THD) of the output voltage, from 5.8% (at full load, uncompensated) to 1.6% (at full load, with compensation). The control method proposed is validated with simulations and experimental tests.
单相逆变器电压谐波消除控制方法的设计与实现
单相电压源变换器广泛应用于并网光伏阵列等电力转换系统中。本文提出了一种单相逆变器的控制方法,旨在降低输出电压的谐波含量,特别是当逆变器馈送峰因数负载时。在这种情况下,电流是非正弦且相对扭曲;因此,THD比规格允许的要高。所提出的方法使用电压控制器和电流控制器,两者都在固定参考系中实现。电压控制器采用基于调制-解调的谐波消除方法。这种方法调节电压的基频,也用于尝试消除一些高次谐波。在本文的仿真和实验中,对电压的基频和三、五、七次谐波进行了调节和谐波消除。该方案可以进一步扩展,以消除更高阶的谐波。结果表明,所提出的控制方法显著降低了输出电压的总谐波失真(THD),从5.8%(满载时,未补偿)降低到1.6%(满载时,有补偿)。通过仿真和实验验证了所提出的控制方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信