Line interactive distributed 4-leg inverter system with unbalanced and nonlinear loads

D. Vyawahare, M. Chandorkar
{"title":"Line interactive distributed 4-leg inverter system with unbalanced and nonlinear loads","authors":"D. Vyawahare, M. Chandorkar","doi":"10.1109/PEDES.2014.7042034","DOIUrl":null,"url":null,"abstract":"This paper is concerned with the distributed line interactive operation of 4-leg inverters. Generally, a 3-leg inverter is used as an inverter interface in distributed systems or microgrids. However 3-leg inverters are incapable in effectively handling the unbalance and nonlinearity in the loads. The 4-leg inverters, on the other hand, can control zero sequence currents and give effective DC link utilization. This feature is utilized here to improve the emergency operation of line interactive system. In case of failure of main power supply, that is in emergency operation, 4-leg inverters can maintain balanced and sinusoidal voltages even if the load is unbalanced and nonlinear. Instead of a dedicated compensator designed for handling load unbalance or nonlinearity, the system is inherently made capable of handling such loads. For line interactive operation the transitions between normal and emergency mode are taken care of by frequency restoration scheme. This allows seamless transitions without any change in control algorithm.","PeriodicalId":124701,"journal":{"name":"2014 IEEE International Conference on Power Electronics, Drives and Energy Systems (PEDES)","volume":"22 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE International Conference on Power Electronics, Drives and Energy Systems (PEDES)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEDES.2014.7042034","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

This paper is concerned with the distributed line interactive operation of 4-leg inverters. Generally, a 3-leg inverter is used as an inverter interface in distributed systems or microgrids. However 3-leg inverters are incapable in effectively handling the unbalance and nonlinearity in the loads. The 4-leg inverters, on the other hand, can control zero sequence currents and give effective DC link utilization. This feature is utilized here to improve the emergency operation of line interactive system. In case of failure of main power supply, that is in emergency operation, 4-leg inverters can maintain balanced and sinusoidal voltages even if the load is unbalanced and nonlinear. Instead of a dedicated compensator designed for handling load unbalance or nonlinearity, the system is inherently made capable of handling such loads. For line interactive operation the transitions between normal and emergency mode are taken care of by frequency restoration scheme. This allows seamless transitions without any change in control algorithm.
负载不平衡非线性的线路交互分布式四腿逆变系统
本文研究了四腿逆变器的分布式线路交互运行。在分布式系统或微电网中,一般采用3腿逆变器作为逆变器接口。然而,三腿逆变器不能有效地处理负载的不平衡和非线性。另一方面,4腿逆变器可以控制零序电流并提供有效的直流链路利用率。利用这一特性来改进线路交互系统的应急运行。当主电源发生故障,即紧急运行时,即使负载不平衡、非线性,四腿逆变器也能保持平衡、正弦电压。而不是专门为处理负载不平衡或非线性设计的补偿器,系统本身就能够处理这样的负载。对于线路交互运行,采用频率恢复方案处理正常模式和应急模式之间的切换。这允许无缝过渡,而不需要改变控制算法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信