New control strategy with CB-P for improved FRT capability of grid-integrated DFIG based wind energy system

Snehaprava Swain, P. K. Ray
{"title":"New control strategy with CB-P for improved FRT capability of grid-integrated DFIG based wind energy system","authors":"Snehaprava Swain, P. K. Ray","doi":"10.1109/ICEES.2016.7510654","DOIUrl":null,"url":null,"abstract":"A new control prospective is adopted in this paper to enhance the Fault Ride Through (FRT) capability of the variable speed Induction Generator along with a Crowbar protection circuit. The Induction Generator is a Doubly Fed Induction Generator (DFIG) used in a Wind Power Conversion System (WPCS). The DFIGs interconnected with the grid are very much sensitive to any disturbance in the grid. The stator of the generator is directly connected to the grid. Hence occurrence of any fault near the grid, immediately leads to a sag in the stator voltage of the generator causing overcurrents as well as overvoltages in the rotor windings. As a result there is a chance of damage of the partial fraction Rotor Side Converter (RSC) during fault. In order to protect the converter, here in this paper a new crowbar protection design is adopted along with the proposed control technique. The proposed strategy is validated through simulation results. The Simulations are carried out in MATLAB on a 1.7 MVA DFIG system and the effectiveness of the new protection design is verified.","PeriodicalId":308604,"journal":{"name":"2016 3rd International Conference on Electrical Energy Systems (ICEES)","volume":"99 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-03-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 3rd International Conference on Electrical Energy Systems (ICEES)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEES.2016.7510654","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

A new control prospective is adopted in this paper to enhance the Fault Ride Through (FRT) capability of the variable speed Induction Generator along with a Crowbar protection circuit. The Induction Generator is a Doubly Fed Induction Generator (DFIG) used in a Wind Power Conversion System (WPCS). The DFIGs interconnected with the grid are very much sensitive to any disturbance in the grid. The stator of the generator is directly connected to the grid. Hence occurrence of any fault near the grid, immediately leads to a sag in the stator voltage of the generator causing overcurrents as well as overvoltages in the rotor windings. As a result there is a chance of damage of the partial fraction Rotor Side Converter (RSC) during fault. In order to protect the converter, here in this paper a new crowbar protection design is adopted along with the proposed control technique. The proposed strategy is validated through simulation results. The Simulations are carried out in MATLAB on a 1.7 MVA DFIG system and the effectiveness of the new protection design is verified.
基于CB-P的并网DFIG风能系统FRT控制策略
本文采用一种新的控制思路,结合撬棍保护电路,提高了变速感应发电机的故障穿越能力。感应发电机是一种用于风力发电转换系统的双馈感应发电机(DFIG)。与电网相连的DFIGs对电网中的任何扰动都非常敏感。发电机的定子直接与电网相连。因此,在电网附近发生任何故障,立即导致发电机的定子电压下降,造成过流以及转子绕组的过电压。因此,部分分数转子侧变换器(RSC)有可能在故障期间损坏。为了保护变流器,本文采用了一种新的撬棍保护设计和提出的控制技术。仿真结果验证了该策略的有效性。在1.7 MVA的DFIG系统上进行了MATLAB仿真,验证了新保护设计的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信