{"title":"Comparative study on single diode photovoltaic module parameter extraction methods","authors":"A. Mohapatra, B. Nayak, Kanungo Barada Mohanty","doi":"10.1109/ICPEC.2013.6527619","DOIUrl":null,"url":null,"abstract":"This paper compares the different approaches for extraction of PV module parameters. The trust-region-doleg method is proposed here for extraction of five parameters such as series resistance (Rs), shunt resistance (Rp), diode ideality factor (a), dark saturation current (I0) and photo-generated current (Ipv) under standard test conditions (STC). The comparative analysis is made by taking Villalva's iterative method and proposed trust-region-dogleg method. Two parameters Rs and Rp are extracted by Villalva's iterative method whereas all five unknown parameters can be extracted by proposed trust-region-dogleg method. The accuracy of parameters calculation depends on tolerance band and initial conditions are tabulated. The PV module behavior at different temperature and irradiance is also forecasted.","PeriodicalId":176900,"journal":{"name":"2013 International Conference on Power, Energy and Control (ICPEC)","volume":"55 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"31","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 International Conference on Power, Energy and Control (ICPEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPEC.2013.6527619","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 31
Abstract
This paper compares the different approaches for extraction of PV module parameters. The trust-region-doleg method is proposed here for extraction of five parameters such as series resistance (Rs), shunt resistance (Rp), diode ideality factor (a), dark saturation current (I0) and photo-generated current (Ipv) under standard test conditions (STC). The comparative analysis is made by taking Villalva's iterative method and proposed trust-region-dogleg method. Two parameters Rs and Rp are extracted by Villalva's iterative method whereas all five unknown parameters can be extracted by proposed trust-region-dogleg method. The accuracy of parameters calculation depends on tolerance band and initial conditions are tabulated. The PV module behavior at different temperature and irradiance is also forecasted.