{"title":"An adaptive three-bus power system equivalent for estimating voltage stability margin from synchronized phasor measurements","authors":"Fengkai Hu, K. Sun, A. del Rosso, E. Farantatos, N. Bhatt","doi":"10.1109/PESGM.2014.6939177","DOIUrl":null,"url":null,"abstract":"This paper utilizes an adaptive three-bus power system equivalent for measurement-based voltage stability analysis. With that equivalent identified online, a measurement-based approach is developed to estimate real-time voltage stability margin for a load-rich area supported by remote generation via multiple tie lines. Compared with traditional Thevenin equivalent based approach, this new approach is able to provide more accurate voltage stability margin for each individual tie line. This approach is validated on a three-bus system and the IEEE 39-bus system.","PeriodicalId":149134,"journal":{"name":"2014 IEEE PES General Meeting | Conference & Exposition","volume":"114 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-07-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"30","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE PES General Meeting | Conference & Exposition","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESGM.2014.6939177","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 30

Abstract

This paper utilizes an adaptive three-bus power system equivalent for measurement-based voltage stability analysis. With that equivalent identified online, a measurement-based approach is developed to estimate real-time voltage stability margin for a load-rich area supported by remote generation via multiple tie lines. Compared with traditional Thevenin equivalent based approach, this new approach is able to provide more accurate voltage stability margin for each individual tie line. This approach is validated on a three-bus system and the IEEE 39-bus system.
从同步相量测量估计电压稳定裕度的自适应三母线电力系统等效
本文采用自适应三母线电力系统等效法进行基于测量的电压稳定性分析。通过在线确定等效电压,开发了一种基于测量的方法,用于估算通过多条联络线远程发电支持的负载丰富地区的实时电压稳定裕度。与传统的基于Thevenin等效的方法相比,该方法能够为每条单独的线路提供更精确的电压稳定裕度。该方法在三总线系统和IEEE 39总线系统上进行了验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信