{"title":"Power Factor Correction and Sensorless Control of PMSM Using FOC Strategy","authors":"C. Nicola, M. Nicola, S. Popescu, M. Duta","doi":"10.1109/SIELMEN.2019.8905841","DOIUrl":null,"url":null,"abstract":"This article presents the sensorless control of a PMSM based on the FOC (Field Oriented Control) strategy and on PFC (Power Factor Correction), where the rotor speed is provided by speed observers. It presents the block structure of the PFC together with the numerical simulations achieved in Matlab/Simulink, on the improvement of the PF (Power Factor) of the supply circuit. It also presents the block structures of the FOC strategy and of the back-EMF (back electromotive force) sliding mode, MRAS (Model Reference Adaptive System), and PLL (Phase Locked Loop) type observers. The numerical simulations show the superiority of rotor speed estimation when using the back-EMF sliding mode observer compared to the rotor speed estimate provided by MRAS and PLL observers.","PeriodicalId":129030,"journal":{"name":"2019 International Conference on Electromechanical and Energy Systems (SIELMEN)","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 International Conference on Electromechanical and Energy Systems (SIELMEN)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SIELMEN.2019.8905841","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4
Abstract
This article presents the sensorless control of a PMSM based on the FOC (Field Oriented Control) strategy and on PFC (Power Factor Correction), where the rotor speed is provided by speed observers. It presents the block structure of the PFC together with the numerical simulations achieved in Matlab/Simulink, on the improvement of the PF (Power Factor) of the supply circuit. It also presents the block structures of the FOC strategy and of the back-EMF (back electromotive force) sliding mode, MRAS (Model Reference Adaptive System), and PLL (Phase Locked Loop) type observers. The numerical simulations show the superiority of rotor speed estimation when using the back-EMF sliding mode observer compared to the rotor speed estimate provided by MRAS and PLL observers.