Impact of Blood Vessels on Data Packet Transmission Through the Fat Channel

N. B. Asan, E. Hassan, S. Redzwan, J. Velander, T. Voigt, R. Augustine
{"title":"Impact of Blood Vessels on Data Packet Transmission Through the Fat Channel","authors":"N. B. Asan, E. Hassan, S. Redzwan, J. Velander, T. Voigt, R. Augustine","doi":"10.1109/RFM.2018.8846488","DOIUrl":null,"url":null,"abstract":"The reliability of intra-body wireless communication systems is very important in medical applications to ensure the data transmission between implanted devices. In this paper, we present newly developed measurements to investigate the effect of blood vessels on the data packet reception through the fat tissue. We use an IEEE 802.15.4-based WBAN prototype to measure the packet reception rate (PRR) through a tissue-equivalent phantom model. The blood vessels are modelled using copper rods. We measure the PRR at the frequency 2.45 GHz for several power levels. The results revealed that the presence of blood vessels aligned with the fat channel has tiny influence on the PRR when measured over the range −25 dBm to 0 dBm power level and for different blood vessels positions. Our investigations show 97% successful PRR through a 10 cm length fat channel in presence of the blood vessels.","PeriodicalId":111726,"journal":{"name":"2018 IEEE International RF and Microwave Conference (RFM)","volume":"25 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE International RF and Microwave Conference (RFM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/RFM.2018.8846488","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The reliability of intra-body wireless communication systems is very important in medical applications to ensure the data transmission between implanted devices. In this paper, we present newly developed measurements to investigate the effect of blood vessels on the data packet reception through the fat tissue. We use an IEEE 802.15.4-based WBAN prototype to measure the packet reception rate (PRR) through a tissue-equivalent phantom model. The blood vessels are modelled using copper rods. We measure the PRR at the frequency 2.45 GHz for several power levels. The results revealed that the presence of blood vessels aligned with the fat channel has tiny influence on the PRR when measured over the range −25 dBm to 0 dBm power level and for different blood vessels positions. Our investigations show 97% successful PRR through a 10 cm length fat channel in presence of the blood vessels.
血管对脂肪通道数据包传输的影响
在医疗应用中,为了保证植入设备之间的数据传输,体内无线通信系统的可靠性非常重要。在本文中,我们提出了新的测量方法来研究血管对通过脂肪组织的数据包接收的影响。我们使用基于IEEE 802.15.4的WBAN原型,通过组织等效幻象模型来测量分组接收速率(PRR)。血管是用铜棒制作的。我们测量了几个功率水平下2.45 GHz频率下的PRR。结果表明,在−25 dBm至0 dBm功率范围内,不同血管位置下,血管与脂肪通道排列的存在对PRR的影响很小。我们的调查显示97%的PRR成功通过一个10厘米长的脂肪通道存在血管。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信