Current Rating Analysis of a Nine-Switch based Unified Expandable Power Converter Considering Different Configurations

H. Bizhani, S. Muyeen, Fatemeh R. Tatari, K. Techato, L. Ben‐Brahim, F. Blaabjerg
{"title":"Current Rating Analysis of a Nine-Switch based Unified Expandable Power Converter Considering Different Configurations","authors":"H. Bizhani, S. Muyeen, Fatemeh R. Tatari, K. Techato, L. Ben‐Brahim, F. Blaabjerg","doi":"10.1109/SPIES48661.2020.9243049","DOIUrl":null,"url":null,"abstract":"Using low switch converters due to their cost-effectiveness has been an interesting topic in different applications such as grid integration of distributed generation systems and multi-machine drives. Recently, a nine-switch based unified expandable power converter (UEPC) has been presented for integration of multi permanent magnet synchronous machine (PMSG) based wind energy systems (WESs) in which the number of switches in comparison with the conventional configurations is significantly reduced. Nevertheless, since all switches are shared between all ports and therefore, the currents of different ports pass through all switches, the current rating of the switches might be higher than the conventional structure. In this paper, to minimize the total required current rating of the semiconductor as well as the installation cost of the UEPC, different acceptable configurations considering different port for grid connection are evaluated and the best port for grid connection is proposed. Finally, to verify the analysis results, the simulation of a three-port version of UEPC is carried out using MATLAB/Simulink software. The simulation results also confirm that when the grid is connected to the middle port, the minimum instantaneous currents pass through the switches.","PeriodicalId":244426,"journal":{"name":"2020 2nd International Conference on Smart Power & Internet Energy Systems (SPIES)","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 2nd International Conference on Smart Power & Internet Energy Systems (SPIES)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SPIES48661.2020.9243049","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Using low switch converters due to their cost-effectiveness has been an interesting topic in different applications such as grid integration of distributed generation systems and multi-machine drives. Recently, a nine-switch based unified expandable power converter (UEPC) has been presented for integration of multi permanent magnet synchronous machine (PMSG) based wind energy systems (WESs) in which the number of switches in comparison with the conventional configurations is significantly reduced. Nevertheless, since all switches are shared between all ports and therefore, the currents of different ports pass through all switches, the current rating of the switches might be higher than the conventional structure. In this paper, to minimize the total required current rating of the semiconductor as well as the installation cost of the UEPC, different acceptable configurations considering different port for grid connection are evaluated and the best port for grid connection is proposed. Finally, to verify the analysis results, the simulation of a three-port version of UEPC is carried out using MATLAB/Simulink software. The simulation results also confirm that when the grid is connected to the middle port, the minimum instantaneous currents pass through the switches.
考虑不同配置的九开关统一可扩展电源变换器的额定电流分析
由于低开关变流器的成本效益,在分布式发电系统的电网集成和多机驱动等不同应用中,使用低开关变流器已成为一个有趣的话题。最近,提出了一种基于9个开关的统一可扩展功率变换器(UEPC),用于集成基于多永磁同步电机(PMSG)的风能系统(WESs),与传统配置相比,该变换器的开关数量显著减少。然而,由于所有交换机在所有端口之间共享,因此,不同端口的电流通过所有交换机,因此交换机的电流额定值可能高于传统结构。为了使半导体所需的总电流额定值和UEPC的安装成本最小,本文在考虑不同的并网端口的情况下,评估了不同的可接受配置,并提出了最佳的并网端口。最后,为了验证分析结果,利用MATLAB/Simulink软件对三端口版本的UEPC进行了仿真。仿真结果还证实,当电网连接到中间端口时,通过开关的瞬时电流最小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信