{"title":"Calculation of voltage unbalance factor in power system supplying traction transformers","authors":"L. Ladniak","doi":"10.1109/PSCC.2014.7038370","DOIUrl":null,"url":null,"abstract":"The article presents the models of transformers with specially connected windings for supplying catenary systems of high-speed rail. Using the symmetrical components method and equations describing the relationship between voltages and currents on the primary and secondary sides of the transformer one can derive equations describing the value of the voltage unbalance factor Eu depending on the transformer power ST and the short-circuit power of the supplying system Ss at the place of connection of the transformer to the supplying grid. The applied procedure allows for estimating voltage unbalance for single-phase, open delta Vv, Way-Delta and Scott as well as Le Blanc, Woodbridge and Roof-Delta transformer connections. The article proves that influence caused by catenary systems of HSR depend on transformer connections, the load and the short-circuit power of the supply network The voltage unbalance factor calculated for various transformer connections can be very useful when choosing an appropriate supplying method and will help create an optimal train rímetable to minimise the unbalance in supplying power system.","PeriodicalId":155801,"journal":{"name":"2014 Power Systems Computation Conference","volume":"2013 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 Power Systems Computation Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PSCC.2014.7038370","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

The article presents the models of transformers with specially connected windings for supplying catenary systems of high-speed rail. Using the symmetrical components method and equations describing the relationship between voltages and currents on the primary and secondary sides of the transformer one can derive equations describing the value of the voltage unbalance factor Eu depending on the transformer power ST and the short-circuit power of the supplying system Ss at the place of connection of the transformer to the supplying grid. The applied procedure allows for estimating voltage unbalance for single-phase, open delta Vv, Way-Delta and Scott as well as Le Blanc, Woodbridge and Roof-Delta transformer connections. The article proves that influence caused by catenary systems of HSR depend on transformer connections, the load and the short-circuit power of the supply network The voltage unbalance factor calculated for various transformer connections can be very useful when choosing an appropriate supplying method and will help create an optimal train rímetable to minimise the unbalance in supplying power system.
牵引变压器供电系统电压不平衡系数的计算
本文介绍了高速铁路接触网供电系统专用绕组变压器的模型。利用对称分量法和描述变压器一次侧和二次侧电压与电流关系的方程,可以推导出描述电压不平衡系数Eu随变压器功率ST和变压器与供电网接入处供电系统短路功率Ss的值的方程。应用程序允许估计单相,开三角Vv, Way-Delta和Scott以及Le Blanc, Woodbridge和Roof-Delta变压器连接的电压不平衡。本文论证了高铁接触网系统对供电系统的影响取决于变压器连接方式、负载和供电网络的短路功率,计算各种变压器连接方式的电压不平衡系数对选择合适的供电方式非常有用,有助于创建最优列车rímetable以最大限度地减少供电系统的不平衡。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信