ANALISIS PERFORMANCE TM2500 GAS TURBINE GENERATOR PACKAGE PLTG X PADA FACTORY TEST DAN SITE TEST

Bina Teknika Pub Date : 2017-12-20 DOI:10.54378/bt.v13i2.214
M. Faizal, B. T. Prasetyo, Eriq Sulton Effendy
{"title":"ANALISIS PERFORMANCE TM2500 GAS TURBINE GENERATOR PACKAGE PLTG X PADA FACTORY TEST DAN SITE TEST","authors":"M. Faizal, B. T. Prasetyo, Eriq Sulton Effendy","doi":"10.54378/bt.v13i2.214","DOIUrl":null,"url":null,"abstract":"Background of this research is to compare the performance of Gas Turbin Power Plant between site test and factory test to make sure that there are no damage on equipment that can cause the decrease of Gas Turbine Performance, and also known the best operation mode in plant. Performance of Gas Turbine Power Plant can be seen from several parameters such as temperature and pressure can be seen from Calculation to be discussed is the work of  compressor, turbine,combustion chamber work, the efficiency of the compressor and thermal efficiency of the cycle brayton effective . The result of performance test show that Gas Turbine performance decrease from 9389,54BTU/kWH and 9409,83 BTU/kWH in factory test to 9944,58 BTU/kWH and 9919.97 BTU/kWH in site test. While the best operation mode occurs when operated on DOHR at 90 to 100% load. Performance of gas turbine is directly proportional to the load. When the load is low, the performance of gas turbine decrease, and when the load is high, the performance of gas turbine increase. This mean that there is a positive correlation between load changes on the performance of gas turbines.","PeriodicalId":441070,"journal":{"name":"Bina Teknika","volume":"33 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-12-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bina Teknika","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.54378/bt.v13i2.214","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Background of this research is to compare the performance of Gas Turbin Power Plant between site test and factory test to make sure that there are no damage on equipment that can cause the decrease of Gas Turbine Performance, and also known the best operation mode in plant. Performance of Gas Turbine Power Plant can be seen from several parameters such as temperature and pressure can be seen from Calculation to be discussed is the work of  compressor, turbine,combustion chamber work, the efficiency of the compressor and thermal efficiency of the cycle brayton effective . The result of performance test show that Gas Turbine performance decrease from 9389,54BTU/kWH and 9409,83 BTU/kWH in factory test to 9944,58 BTU/kWH and 9919.97 BTU/kWH in site test. While the best operation mode occurs when operated on DOHR at 90 to 100% load. Performance of gas turbine is directly proportional to the load. When the load is low, the performance of gas turbine decrease, and when the load is high, the performance of gas turbine increase. This mean that there is a positive correlation between load changes on the performance of gas turbines.
分析tm2500燃气轮机发电机组PLTG x paada工厂试验和现场试验的性能
本研究的背景是通过现场试验和工厂试验对燃气轮机发电厂的性能进行比较,以确保设备没有损坏导致燃气轮机性能下降,并了解电厂的最佳运行模式。燃气轮机电厂的性能可以从温度和压力等几个参数看出,从计算中可以看出要讨论的是压气机的功、涡轮的功、燃烧室的功、压气机的效率和布雷顿循环的热效率的有效性。性能试验结果表明,燃气轮机性能从工厂试验的9389、54BTU/kWH和9409、83 BTU/kWH下降到现场试验的9944、58 BTU/kWH和9919.97 BTU/kWH。而最佳运行模式发生在负载为90%到100%的DOHR上。燃气轮机的性能与负荷成正比。负荷低时,燃气轮机性能下降,负荷高时,燃气轮机性能提高。这意味着,有一个正相关之间的负荷变化对燃气轮机的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信