{"title":"Lumped Element RF Low Pass Filter with 20 dB Improved Suppression at the Center Frequency of an RF Injection Network for Conductive Emission Testing","authors":"A. Attaran, W. Handler, B. Chronik","doi":"10.1109/CCECE.2019.8861975","DOIUrl":null,"url":null,"abstract":"In this work, a modified low pass filter with 20 dB improved rejection at the center frequency of the RF injection network was developed to monitor the RF rectification of an active implantable medical devices (AIMD) during conductive emission testing. Transfer function of the designed filter was calculated, verified and validated by ADS simulation and S-parameter measurement using RF network analyzer. Analytical calculation, simulation and measurement results of the filter transfer function are in good agreement.","PeriodicalId":352860,"journal":{"name":"2019 IEEE Canadian Conference of Electrical and Computer Engineering (CCECE)","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-05-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE Canadian Conference of Electrical and Computer Engineering (CCECE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CCECE.2019.8861975","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In this work, a modified low pass filter with 20 dB improved rejection at the center frequency of the RF injection network was developed to monitor the RF rectification of an active implantable medical devices (AIMD) during conductive emission testing. Transfer function of the designed filter was calculated, verified and validated by ADS simulation and S-parameter measurement using RF network analyzer. Analytical calculation, simulation and measurement results of the filter transfer function are in good agreement.
用于导电发射测试的射频注入网络中心频率处具有20 dB改进抑制的集总元件射频低通滤波器
在这项工作中,开发了一种改进的低通滤波器,在射频注入网络的中心频率处提高了20 dB的抑制,用于监测有源植入式医疗器械(AIMD)在导电发射测试中的射频整流。通过ADS仿真和射频网络分析仪的s参数测量,对所设计滤波器的传递函数进行了计算和验证。滤波器传递函数的解析计算、仿真和实测结果吻合较好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信