Harmonic Resonance Characteristics of a Residential Low Voltage Distribution Network Considering Typical Variations of Grid and Customer Characteristics
{"title":"Harmonic Resonance Characteristics of a Residential Low Voltage Distribution Network Considering Typical Variations of Grid and Customer Characteristics","authors":"Stephan Scholtz, S. Kannan, Jan Meyer","doi":"10.1109/ICHQP53011.2022.9808812","DOIUrl":null,"url":null,"abstract":"Harmonic resonances are increasingly observed in various central European networks, which are impacted by complex parameters. This paper considers the impact of variation in both grid-side and customer-side parameters. The grid-side variations include a change in cable lengths and the distribution of customers. The customer-side variations include the time-dependent combination of various household appliances and the resulting unbalance. In this paper, comprehensive simulation studies in a residential low voltage network show that the resonance frequency remains predominantly constant at various locations for simultaneous variation in different network parameters.","PeriodicalId":249133,"journal":{"name":"2022 20th International Conference on Harmonics & Quality of Power (ICHQP)","volume":"31 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 20th International Conference on Harmonics & Quality of Power (ICHQP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHQP53011.2022.9808812","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
Abstract
Harmonic resonances are increasingly observed in various central European networks, which are impacted by complex parameters. This paper considers the impact of variation in both grid-side and customer-side parameters. The grid-side variations include a change in cable lengths and the distribution of customers. The customer-side variations include the time-dependent combination of various household appliances and the resulting unbalance. In this paper, comprehensive simulation studies in a residential low voltage network show that the resonance frequency remains predominantly constant at various locations for simultaneous variation in different network parameters.