{"title":"A novel smectite-polymer nanocomposite (SPN) microstrip sensor for rapid quantitative detection of aflatoxins","authors":"He Hu, Jun Zou, Youjun Deng","doi":"10.1109/ICSENS.2013.6688585","DOIUrl":null,"url":null,"abstract":"This paper reports the development of a novel smectite-polymer nanocomposite (SPN) microstrip sensor for both rapid quantification and long-term monitoring of aflatoxins. The smectite was modified with Ba2002B; cation exchange to improve its aflatoxin adsorption. SPN thin-films were synthesized on silicon substrates via layer-by-layer self-assembly. SPN microstrip arrays were patterned on glass substrates using stencil masks and enclosed in a microfluidic channel. This reduces the diffusion length and the adsorption time of aflatoxins, thereby resulting in fast response time (<; 10 min). A simple fluorometric quantification of aflatoxin concentration based on incident intensity modulation was developed to eliminate the need of a sophisticated fluorometer. A low detection limit of 6.09 ppb and a wide linear range of 5~80 ppb for aflatoxin B1 have been achieved.","PeriodicalId":258260,"journal":{"name":"2013 IEEE SENSORS","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-12-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE SENSORS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENS.2013.6688585","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
This paper reports the development of a novel smectite-polymer nanocomposite (SPN) microstrip sensor for both rapid quantification and long-term monitoring of aflatoxins. The smectite was modified with Ba2002B; cation exchange to improve its aflatoxin adsorption. SPN thin-films were synthesized on silicon substrates via layer-by-layer self-assembly. SPN microstrip arrays were patterned on glass substrates using stencil masks and enclosed in a microfluidic channel. This reduces the diffusion length and the adsorption time of aflatoxins, thereby resulting in fast response time (<; 10 min). A simple fluorometric quantification of aflatoxin concentration based on incident intensity modulation was developed to eliminate the need of a sophisticated fluorometer. A low detection limit of 6.09 ppb and a wide linear range of 5~80 ppb for aflatoxin B1 have been achieved.