Correlation between axial length, anterior chamber depth, and other biometric measurements with iol master 700 in normal eyes, short eyes, long eyes, and extremely long eyes in latin american population

C. R. Rodríguez López, Guadalupe Mora Gonzalez, J. Félix, Saira Perez Garcia, Miguel Ibáñez Hernández, A. Muñoz
{"title":"Correlation between axial length, anterior chamber depth, and other biometric measurements with iol master 700 in normal eyes, short eyes, long eyes, and extremely long eyes in latin american population","authors":"C. R. Rodríguez López, Guadalupe Mora Gonzalez, J. Félix, Saira Perez Garcia, Miguel Ibáñez Hernández, A. Muñoz","doi":"10.4103/pajo.pajo_42_20","DOIUrl":null,"url":null,"abstract":"Background: Several studies have shown the correlation between ocular biometry with refractive errors. Since these parameters can be influenced by race, ethnicity, and genetics, their differences between different populations can probably explain the differences in refractive errors. We present the biometric values measured in 431 eyes with normal, short, long, and extremely long axial length (AL) from the Latin American population. Patients and Methods: All eye measurements were performed using optical biometry with IOL Master and stratified according to AL and anterior chamber depth (ACD) and evaluated in relation to each other. Symmetry between right eye (RE) and left eye (LE) was also analyzed. Setting: The study was conducted at Private practice, Guadalajara, Jalisco, Mexico. Results: ACD, white-to-white (WTW), and average keratometries (K) increase as AL increases in normal, short, and long eyes, but this correlation is not maintained in extremely long eyes. Most of the short eyes and eyes with normal AL have a normal ACD, but most of the long and extremely long eyes have an ACD >2.5 mm. In normal and short eyes, the AL and WTW are symmetric in both eyes, but in long and extremely long eyes, there are significant differences between RE and LE. ACD is symmetric in RE and LE regardless of AL. Conclusions: The importance of the ocular biometry in Latin American eyes relies on clarifying the assumptions of biometric measurements commonly used in various areas of ophthalmology including intraocular lens calculation formulas.","PeriodicalId":378703,"journal":{"name":"The Pan-American Journal of Ophthalmology","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Pan-American Journal of Ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/pajo.pajo_42_20","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Several studies have shown the correlation between ocular biometry with refractive errors. Since these parameters can be influenced by race, ethnicity, and genetics, their differences between different populations can probably explain the differences in refractive errors. We present the biometric values measured in 431 eyes with normal, short, long, and extremely long axial length (AL) from the Latin American population. Patients and Methods: All eye measurements were performed using optical biometry with IOL Master and stratified according to AL and anterior chamber depth (ACD) and evaluated in relation to each other. Symmetry between right eye (RE) and left eye (LE) was also analyzed. Setting: The study was conducted at Private practice, Guadalajara, Jalisco, Mexico. Results: ACD, white-to-white (WTW), and average keratometries (K) increase as AL increases in normal, short, and long eyes, but this correlation is not maintained in extremely long eyes. Most of the short eyes and eyes with normal AL have a normal ACD, but most of the long and extremely long eyes have an ACD >2.5 mm. In normal and short eyes, the AL and WTW are symmetric in both eyes, but in long and extremely long eyes, there are significant differences between RE and LE. ACD is symmetric in RE and LE regardless of AL. Conclusions: The importance of the ocular biometry in Latin American eyes relies on clarifying the assumptions of biometric measurements commonly used in various areas of ophthalmology including intraocular lens calculation formulas.
拉丁美洲人群正常眼、短眼、长眼和极长眼的眼轴长度、前房深度和其他生物特征测量与iol大师700的相关性
背景:一些研究表明,眼部生物测量与屈光不正之间存在相关性。由于这些参数可能受到种族、民族和遗传的影响,因此它们在不同人群之间的差异可能可以解释屈光不正的差异。我们介绍了来自拉丁美洲人群的431只正常、短、长和极长轴长(AL)眼睛的生物特征值。患者和方法:采用人工晶状体(IOL Master)光学生物测量技术,根据AL和前房深度(ACD)进行分层,并相互评价。右眼(RE)和左眼(LE)的对称性也进行了分析。环境:该研究在墨西哥哈利斯科州瓜达拉哈拉的私人诊所进行。结果:在正常眼、短眼和长眼中,ACD、白对白(WTW)和平均角膜屈光度(K)随AL的增加而增加,但在极长眼中不保持这种相关性。大部分短眼和AL正常眼的ACD正常,而大部分长眼和极长眼的ACD >2.5 mm。在正常眼和短眼中,AL和WTW在双眼中是对称的,但在长眼和极长眼中,RE和LE之间存在显著差异。结论:拉丁美洲人眼生物测量的重要性在于澄清眼科各领域常用的生物测量假设,包括人工晶状体计算公式。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书