Power quality immunity in factory automation

A. Moreno-Muñoz, J. Flores-Arias, V. Pallarés, J. D. L. de la Rosa
{"title":"Power quality immunity in factory automation","authors":"A. Moreno-Muñoz, J. Flores-Arias, V. Pallarés, J. D. L. de la Rosa","doi":"10.1109/CPE.2009.5156006","DOIUrl":null,"url":null,"abstract":"Voltage sag analysis is a complex stochastic issue, since it involves a large variety of random factors, such as: type of short-circuits in the power system, location of faults, protective system performance and atmospheric discharges. Among all categories of electrical disturbances, the voltage sag (dip) and momentary interruption are the nemeses of the automated industrial process. This paper presents results from two power quality audit conducted in different highly automated factories. In both cases it was found that the main problems for the equipment installed were voltage sags. The paper analyzes the capabilities of modern power supplies; the convenience of “embedded solution” is also discussed. Finally it is addressed the role of the Standards on the protection of electronic equipment.","PeriodicalId":272748,"journal":{"name":"2009 Compatibility and Power Electronics","volume":"164 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 Compatibility and Power Electronics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPE.2009.5156006","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

Abstract

Voltage sag analysis is a complex stochastic issue, since it involves a large variety of random factors, such as: type of short-circuits in the power system, location of faults, protective system performance and atmospheric discharges. Among all categories of electrical disturbances, the voltage sag (dip) and momentary interruption are the nemeses of the automated industrial process. This paper presents results from two power quality audit conducted in different highly automated factories. In both cases it was found that the main problems for the equipment installed were voltage sags. The paper analyzes the capabilities of modern power supplies; the convenience of “embedded solution” is also discussed. Finally it is addressed the role of the Standards on the protection of electronic equipment.
工厂自动化中的电能质量抗扰度
电压暂降分析是一个复杂的随机问题,涉及多种随机因素,如电力系统短路类型、故障位置、保护系统性能、大气放电等。在所有类型的电气干扰中,电压骤降和瞬间中断是自动化工业过程的克星。本文介绍了在不同的高度自动化工厂进行的两次电能质量审计的结果。在这两个案例中,发现设备安装的主要问题是电压跌落。本文分析了现代电源的性能;文中还讨论了“嵌入式解决方案”的便利性。最后讨论了电子设备保护标准的作用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信