The feasibility of developing a 64-elements cylindrical phased array for intraductal thermal ablation

D. Melodelima, C. Lafon, F. Prat, A. Birer, Y. Theillère, D. Cathignol
{"title":"The feasibility of developing a 64-elements cylindrical phased array for intraductal thermal ablation","authors":"D. Melodelima, C. Lafon, F. Prat, A. Birer, Y. Theillère, D. Cathignol","doi":"10.1109/ULTSYM.2002.1192576","DOIUrl":null,"url":null,"abstract":"In this study, the feasibility of a cylindrical phased array (10-mm O.D.) has been evaluated for intraductal thermal ablation. The principle of this applicator is to generate electronically rotating plane waves. A plane propagation is generated by exciting eight successive elements with appropriate excitation delay times. The shot direction was changed by exciting a different set of eight elements. In the future, the final applicator will be composed of 64 elements arranged all over the periphery of the cylinder. This study present a cylindrical prototype (10.6-mm O.D.) which is composed of 16 transducers working at 4.55 MHz and arranged on a quarter of the cylinder. The dimension of each transducer is 15 /spl times/ 0.45 mm/sup 2/ and the distance between two consecutive elements is 70-/spl mu/m. The mechanical strength of the device was reinforced by mounting a rigid damper structure on the rear face of the active part. Heat dissipation is favoured by the thermal properties of the backing. The active part is covered by a latex balloon and cooled internally and externally by a continuous flow of degassed water. This study showed that the ultrasound beam generated by eight elements excited with appropriated delay times is plane. Ex vivo experiments were carried out on pig liver and permit to generated three reproducible well-defined lesions up to 14-mm, separated from each other by a 23/spl deg/ angle.","PeriodicalId":378705,"journal":{"name":"2002 IEEE Ultrasonics Symposium, 2002. Proceedings.","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-10-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2002 IEEE Ultrasonics Symposium, 2002. Proceedings.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ULTSYM.2002.1192576","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In this study, the feasibility of a cylindrical phased array (10-mm O.D.) has been evaluated for intraductal thermal ablation. The principle of this applicator is to generate electronically rotating plane waves. A plane propagation is generated by exciting eight successive elements with appropriate excitation delay times. The shot direction was changed by exciting a different set of eight elements. In the future, the final applicator will be composed of 64 elements arranged all over the periphery of the cylinder. This study present a cylindrical prototype (10.6-mm O.D.) which is composed of 16 transducers working at 4.55 MHz and arranged on a quarter of the cylinder. The dimension of each transducer is 15 /spl times/ 0.45 mm/sup 2/ and the distance between two consecutive elements is 70-/spl mu/m. The mechanical strength of the device was reinforced by mounting a rigid damper structure on the rear face of the active part. Heat dissipation is favoured by the thermal properties of the backing. The active part is covered by a latex balloon and cooled internally and externally by a continuous flow of degassed water. This study showed that the ultrasound beam generated by eight elements excited with appropriated delay times is plane. Ex vivo experiments were carried out on pig liver and permit to generated three reproducible well-defined lesions up to 14-mm, separated from each other by a 23/spl deg/ angle.
用于导管内热烧蚀的64元圆柱相控阵的可行性
在本研究中,评估了圆柱形相控阵(外径10毫米)用于导管内热烧蚀的可行性。这种涂敷器的原理是产生电子旋转平面波。通过适当的激励延迟时间,激励八个连续的单元,产生一个平面传播。通过刺激不同的八种元素来改变拍摄方向。将来,最终的涂抹器将由64个元件组成,这些元件排列在圆柱体的外围。本研究提出了一个圆柱形原型(10.6 mm外径),它由16个工作频率为4.55 MHz的换能器组成,并排列在圆柱体的四分之一上。每个换能器的尺寸为15 /spl倍/ 0.45 mm/sup 2/,两个连续元件之间的距离为70-/spl mu/m。该装置的机械强度是通过安装一个刚性阻尼结构的后表面的主动部分加强。背衬的热特性有利于散热。活性部分由乳胶气球覆盖,并通过连续的脱气水在内部和外部进行冷却。研究表明,在适当的延时时间激发下,8个元件产生的超声波束是平面的。在猪肝上进行了离体实验,并允许产生三个可重复的明确定义的病变,最大可达14mm,彼此相隔23/spl度/角。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信