Analysis of Accident Caused by One Point Ground Fault in DC System

Jin Zou, Kansheng Yu, G. Xie, Zhicheng Wang, Yangqi Huang, Yong Wan, Wei Zeng, Ning Zhou, Zhan Shu, Ying Wu, Jianming Yang, Yifeng Li
{"title":"Analysis of Accident Caused by One Point Ground Fault in DC System","authors":"Jin Zou, Kansheng Yu, G. Xie, Zhicheng Wang, Yangqi Huang, Yong Wan, Wei Zeng, Ning Zhou, Zhan Shu, Ying Wu, Jianming Yang, Yifeng Li","doi":"10.1109/ICCTEC.2017.00211","DOIUrl":null,"url":null,"abstract":"This paper studies mechanism of the action occurring when one point ground fault happens through the analysis of an accident caused by one point ground fault in DC system. This paper points out that relay action will be possible in the case of one point ground fault in DC system through capacitor's discharging if the distributed capacitance reaches a certain magnitude. Finally, this paper proposes corresponding solutions such as increasing relay interference and transforming the DC insulation monitoring devices in order to avoid such accidents.","PeriodicalId":267944,"journal":{"name":"2017 International Conference on Computer Technology, Electronics and Communication (ICCTEC)","volume":"51 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 International Conference on Computer Technology, Electronics and Communication (ICCTEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICCTEC.2017.00211","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

This paper studies mechanism of the action occurring when one point ground fault happens through the analysis of an accident caused by one point ground fault in DC system. This paper points out that relay action will be possible in the case of one point ground fault in DC system through capacitor's discharging if the distributed capacitance reaches a certain magnitude. Finally, this paper proposes corresponding solutions such as increasing relay interference and transforming the DC insulation monitoring devices in order to avoid such accidents.
直流系统一点接地故障事故分析
本文通过对一起直流系统单点接地故障事故的分析,研究了单点接地故障发生时的作用机理。指出在直流系统中,当分布电容达到一定量级时,通过电容放电发生一点接地故障时,可以进行继电动作。最后,本文提出了相应的解决方案,如增加继电器干扰和改造直流绝缘监控装置,以避免此类事故的发生。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书