Inductive contactless power transfer system with coaxial coreless transformer for dc power distribution

Satoshi Ojika, Y. Miura, T. Ise
{"title":"Inductive contactless power transfer system with coaxial coreless transformer for dc power distribution","authors":"Satoshi Ojika, Y. Miura, T. Ise","doi":"10.1109/ECCE-ASIA.2013.6579237","DOIUrl":null,"url":null,"abstract":"This paper proposes to use contactless power transfer (CPT) systems as electric plugs and outlets for household dc distribution system. In dc systems, there are higher risk of electric shock and longer arc discharge at disconnection compared with ac systems. The proposed system can connect and disconnect safely without electric shock and arc discharge because there is no contactor between primary side and secondary side. In this paper, an inductive contactless power transfer system was adopted. To reduce cost of system, a coreless transformer was selected. CPT circuit topologies and design of transformer coil form were considered. As suitable structure, a coaxial cylindrical transformer was proposed. Simulation results of 1 kW 400 kHz model and experimental results of developed 1 kW 400 kHz and 600 kHz prototypes were presented. The proposed system showed maximum efficiency over 93%.","PeriodicalId":301487,"journal":{"name":"2013 IEEE ECCE Asia Downunder","volume":"73 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-06-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"15","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE ECCE Asia Downunder","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ECCE-ASIA.2013.6579237","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15

Abstract

This paper proposes to use contactless power transfer (CPT) systems as electric plugs and outlets for household dc distribution system. In dc systems, there are higher risk of electric shock and longer arc discharge at disconnection compared with ac systems. The proposed system can connect and disconnect safely without electric shock and arc discharge because there is no contactor between primary side and secondary side. In this paper, an inductive contactless power transfer system was adopted. To reduce cost of system, a coreless transformer was selected. CPT circuit topologies and design of transformer coil form were considered. As suitable structure, a coaxial cylindrical transformer was proposed. Simulation results of 1 kW 400 kHz model and experimental results of developed 1 kW 400 kHz and 600 kHz prototypes were presented. The proposed system showed maximum efficiency over 93%.
直流配电用同轴无芯变压器感应无触点输电系统
本文提出采用非接触式电力传输系统作为家用直流配电系统的电源插头和插座。在直流系统中,与交流系统相比,在断开时有更高的触电风险和更长的电弧放电。由于在一次侧和二次侧之间没有接触器,该系统可以安全地连接和断开,不会产生触电和电弧放电。本文采用一种感应式非接触式电力传输系统。为降低系统成本,选用无铁芯变压器。考虑了CPT电路拓扑结构和变压器线圈形式的设计。作为合适的结构,提出了同轴圆柱形变压器。给出了1 kW 400 kHz样机的仿真结果和研制的1 kW 400 kHz样机和600 kHz样机的实验结果。该系统的最高效率超过93%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信